15 Drug-coated balloon angioplasty versus drug-eluting stent implantation for the treatment of bare-metal and drug-eluting stent restenosis: results from the daedalus study

D. Giacoppo, Fernando Alfonso, Adnan Kastrati, R. A. Byrne
{"title":"15 Drug-coated balloon angioplasty versus drug-eluting stent implantation for the treatment of bare-metal and drug-eluting stent restenosis: results from the daedalus study","authors":"D. Giacoppo, Fernando Alfonso, Adnan Kastrati, R. A. Byrne","doi":"10.1136/HEARTJNL-2020-ICS.15","DOIUrl":null,"url":null,"abstract":"Background In patients with coronary in-stent restenosis (ISR) requiring re-intervention, it is unclear if the choice of treatment strategy depends on whether the restenotic stent was a bare-metal stent (BMS) or a drug-eluting stent (DES). Objectives We aimed to assess the comparative efficacy and safety of the two most frequently used treatments – angioplasty with drug-coated balloon (DCB) and repeat stenting DES – in patients with BMS- and DES-ISR. Methods The DAEDALUS study was a pooled analysis of individual patient data from all 10 existing randomized clinical trials comparing DCB angioplasty vs. repeat DES implantation for the treatment of coronary ISR. In this prespecified analysis, patients were stratified according to BMS- vs. DES-ISR, and treatment assigned. The primary efficacy endpoint was target lesion revascularization (TLR) at 3 years. The primary safety endpoint was a composite of all-cause death, myocardial infarction, or target lesion thrombosis at 3 years. Primary analysis was performed by Cox mixed-effects models accounting for the trial of origin. Secondary analyses included non-parsimonious multivariable adjustment accounting also for multiple lesions per patient and two-stage analyses. Results A total of 710 patients with BMS-ISR (722 lesions) and 1248 with DES-ISR (1377 lesions) were included. In patients with BMS-ISR, no significant difference between treatments was observed in terms of primary efficacy (9.2% vs. 10.2%; HR 0.83, 95% CI 0.51–1.37) and safety endpoints (8.7% vs. 7.5%; HR 1.13, 95% CI 0.65–1.96); results of secondary analyses were consistent. In patients with DES-ISR, the risk of the primary efficacy endpoint was higher with DCB angioplasty compared with repeat DES implantation (20.3% vs. 13.4%; HR 1.58, 95% CI 1.16–2.13), while the risk of the primary safety endpoint was only numerically lower (9.5% vs. 13.3%; HR 0.69, 95% CI 0.47–1.00) and interaction was not significant (p=0.146); results of secondary analyses were consistent. The risk of TLR was lower in BMS- vs. DES-ISR (9.7% vs. 17.0%; HR 0.57, 95% CI 0.42–0.74), while safety was not significantly different between ISR types. Conclusions At 3-year follow-up, DCB angioplasty and repeat stenting with DES are similarly effective and safe in the treatment of BMS-ISR, while DCB angioplasty is significantly less effective than repeat DES implantation in the treatment DES-ISR without statistically significant differences in safety endpoints. Overall, DES-ISR is associated with higher rates of treatment failure and similar safety compared with BMS-ISR.","PeriodicalId":329496,"journal":{"name":"Oral abstract presentations 2","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral abstract presentations 2","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/HEARTJNL-2020-ICS.15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background In patients with coronary in-stent restenosis (ISR) requiring re-intervention, it is unclear if the choice of treatment strategy depends on whether the restenotic stent was a bare-metal stent (BMS) or a drug-eluting stent (DES). Objectives We aimed to assess the comparative efficacy and safety of the two most frequently used treatments – angioplasty with drug-coated balloon (DCB) and repeat stenting DES – in patients with BMS- and DES-ISR. Methods The DAEDALUS study was a pooled analysis of individual patient data from all 10 existing randomized clinical trials comparing DCB angioplasty vs. repeat DES implantation for the treatment of coronary ISR. In this prespecified analysis, patients were stratified according to BMS- vs. DES-ISR, and treatment assigned. The primary efficacy endpoint was target lesion revascularization (TLR) at 3 years. The primary safety endpoint was a composite of all-cause death, myocardial infarction, or target lesion thrombosis at 3 years. Primary analysis was performed by Cox mixed-effects models accounting for the trial of origin. Secondary analyses included non-parsimonious multivariable adjustment accounting also for multiple lesions per patient and two-stage analyses. Results A total of 710 patients with BMS-ISR (722 lesions) and 1248 with DES-ISR (1377 lesions) were included. In patients with BMS-ISR, no significant difference between treatments was observed in terms of primary efficacy (9.2% vs. 10.2%; HR 0.83, 95% CI 0.51–1.37) and safety endpoints (8.7% vs. 7.5%; HR 1.13, 95% CI 0.65–1.96); results of secondary analyses were consistent. In patients with DES-ISR, the risk of the primary efficacy endpoint was higher with DCB angioplasty compared with repeat DES implantation (20.3% vs. 13.4%; HR 1.58, 95% CI 1.16–2.13), while the risk of the primary safety endpoint was only numerically lower (9.5% vs. 13.3%; HR 0.69, 95% CI 0.47–1.00) and interaction was not significant (p=0.146); results of secondary analyses were consistent. The risk of TLR was lower in BMS- vs. DES-ISR (9.7% vs. 17.0%; HR 0.57, 95% CI 0.42–0.74), while safety was not significantly different between ISR types. Conclusions At 3-year follow-up, DCB angioplasty and repeat stenting with DES are similarly effective and safe in the treatment of BMS-ISR, while DCB angioplasty is significantly less effective than repeat DES implantation in the treatment DES-ISR without statistically significant differences in safety endpoints. Overall, DES-ISR is associated with higher rates of treatment failure and similar safety compared with BMS-ISR.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
药物包被球囊血管成形术与药物洗脱支架植入治疗裸金属和药物洗脱支架再狭窄:来自代达罗斯研究的结果
对于需要再干预的冠状动脉支架内再狭窄(ISR)患者,目前尚不清楚治疗策略的选择是否取决于再狭窄支架是裸金属支架(BMS)还是药物洗脱支架(DES)。我们的目的是评估两种最常用的治疗方法——药物包被球囊血管成形术(DCB)和重复支架植入DES——在BMS-和DES- isr患者中的比较疗效和安全性。方法:DAEDALUS研究是对所有10个现有随机临床试验的个体患者数据进行汇总分析,比较DCB血管成形术与重复DES植入治疗冠状动脉ISR。在这个预先指定的分析中,根据BMS- vs. DES-ISR对患者进行分层,并分配治疗方案。主要疗效终点为3年靶病变血运重建术(TLR)。主要安全终点是3年时全因死亡、心肌梗死或靶病变血栓形成的综合指标。采用Cox混合效应模型进行初步分析,考虑了起源试验。二级分析包括非简约的多变量调整,也考虑了每个患者的多个病变和两阶段分析。结果共纳入BMS-ISR 710例(722个病变)和DES-ISR 1248例(1377个病变)。在BMS-ISR患者中,两种治疗方法在主要疗效方面无显著差异(9.2% vs 10.2%;HR 0.83, 95% CI 0.51-1.37)和安全性终点(8.7% vs. 7.5%;Hr 1.13, 95% ci 0.65-1.96);二次分析结果一致。在DES- isr患者中,与重复DES植入相比,DCB血管成形术的主要疗效终点风险更高(20.3% vs. 13.4%;HR 1.58, 95% CI 1.16-2.13),而主要安全终点的风险仅在数值上较低(9.5%对13.3%;HR 0.69, 95% CI 0.47-1.00),交互作用无统计学意义(p=0.146);二次分析结果一致。BMS-组TLR风险低于DES-ISR组(9.7% vs. 17.0%;HR 0.57, 95% CI 0.42-0.74),而ISR类型之间的安全性无显著差异。结论在3年随访中,DCB血管成形术与DES重复支架植入治疗BMS-ISR的有效性和安全性相似,而DCB血管成形术治疗DES- isr的有效性明显低于重复DES植入,安全性终点无统计学差异。总体而言,与BMS-ISR相比,DES-ISR具有更高的治疗失败率和相似的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
16 The effects of nocturnal blood pressure dipping pattern on cardiac structure assessed using transthoracic echocardiography (TTE) and cardiovascular magnetic resonance (CMR) 14 Morbidly obese patients with symptomatic severe aortic stenosis, what is the optimal treatment strategy? A propensity score matched analysis of transcatheter versus surgical aortic valve replacement 17 Heart rate recovery following active stand test in patients with versus without severe aortic stenosis 13 A CT coronary angiography first strategy in patients determined to have an indication for invasive coronary angiogram: a meta-analysis 15 Drug-coated balloon angioplasty versus drug-eluting stent implantation for the treatment of bare-metal and drug-eluting stent restenosis: results from the daedalus study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1