Enzyme-free photoelectrochemical sensing of glucose based on the TiO2/CuO heterojunction

Shengchen Ke, Ruoxi Zhang, Weijian Zhu, Wenxiang Lu, Lu Ma, Linling Qin, Shaolong Wu
{"title":"Enzyme-free photoelectrochemical sensing of glucose based on the TiO2/CuO heterojunction","authors":"Shengchen Ke, Ruoxi Zhang, Weijian Zhu, Wenxiang Lu, Lu Ma, Linling Qin, Shaolong Wu","doi":"10.1117/12.2684880","DOIUrl":null,"url":null,"abstract":"Conventional enzyme-based glucose sensors have good selectivity and sensing performance, but the disadvantages of the enzyme itself (enzyme activity is susceptible to pH and temperature) lead to a limited number of uses and result in high costs. Therefore, photoelectrochemical enzyme-free glucose sensors have attracted research interest in recent years. In this work, the TiO2/CuO heterojunction was constructed and photoelectrochemical enzyme-free glucose sensing was realized. The sensing sensitivity of the TiO2/CuO heterojunction photoelectrode prepared by magnetron sputtering and thermal annealing process was 864 μAμM-1 cm-2 in the range of 1–9 mM with a detection limit of 58.6 μM at 0.2 V, exhibiting satisfactory stability as well as interference resistance. This better sensing performance mainly comes from: 1) the absorption of photogenerated carriers generated from sunlight by TiO2 films, which participate in glucose redox; 2) the conversion of the metal valence state (Cu2+/Cu3+) of the P-type semiconductor CuO under alkaline conditions can promote glucose redox; 3) the heterojunction formed by CuO and TiO2 reducing the compounding of photogenerated carriers thus improving the photoelectric conversion efficiency. The heterojunction formed by CuO and TiO2 greatly facilitates the surface carrier transfer of glucose oxidation reaction. This work provides a new way for enzyme-free glucose sensing and promotes the development of glucose detection technology.","PeriodicalId":184319,"journal":{"name":"Optical Frontiers","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optical Frontiers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2684880","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Conventional enzyme-based glucose sensors have good selectivity and sensing performance, but the disadvantages of the enzyme itself (enzyme activity is susceptible to pH and temperature) lead to a limited number of uses and result in high costs. Therefore, photoelectrochemical enzyme-free glucose sensors have attracted research interest in recent years. In this work, the TiO2/CuO heterojunction was constructed and photoelectrochemical enzyme-free glucose sensing was realized. The sensing sensitivity of the TiO2/CuO heterojunction photoelectrode prepared by magnetron sputtering and thermal annealing process was 864 μAμM-1 cm-2 in the range of 1–9 mM with a detection limit of 58.6 μM at 0.2 V, exhibiting satisfactory stability as well as interference resistance. This better sensing performance mainly comes from: 1) the absorption of photogenerated carriers generated from sunlight by TiO2 films, which participate in glucose redox; 2) the conversion of the metal valence state (Cu2+/Cu3+) of the P-type semiconductor CuO under alkaline conditions can promote glucose redox; 3) the heterojunction formed by CuO and TiO2 reducing the compounding of photogenerated carriers thus improving the photoelectric conversion efficiency. The heterojunction formed by CuO and TiO2 greatly facilitates the surface carrier transfer of glucose oxidation reaction. This work provides a new way for enzyme-free glucose sensing and promotes the development of glucose detection technology.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于TiO2/CuO异质结的葡萄糖无酶光电化学传感
传统的酶基葡萄糖传感器具有良好的选择性和传感性能,但酶本身的缺点(酶活性易受pH和温度的影响)导致使用数量有限,成本高。因此,光电化学无酶葡萄糖传感器成为近年来研究的热点。在这项工作中,构建了TiO2/CuO异质结,实现了光电化学无酶葡萄糖传感。采用磁控溅射和热退火法制备的TiO2/CuO异质结光电极在1 ~ 9 mM范围内的传感灵敏度为864 μAμM-1 cm-2,在0.2 V下的检出限为58.6 μM,具有良好的稳定性和抗干扰性。这种更好的传感性能主要来自:1)TiO2薄膜吸收太阳光产生的光生载流子,参与葡萄糖氧化还原;2) p型半导体CuO在碱性条件下金属价态(Cu2+/Cu3+)的转换能促进葡萄糖的氧化还原;3) CuO与TiO2形成的异质结减少了光生载流子的复合,从而提高了光电转换效率。CuO与TiO2形成的异质结极大地促进了葡萄糖氧化反应的表面载流子转移。这项工作为无酶葡萄糖传感提供了一条新的途径,促进了葡萄糖检测技术的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Intelligent measuring device and method for large grinding wheel size Fast high-resolution imaging combining deep learning and single-pixel imaging Anomalous wetting behaviors of hierarchical micro-nanostructures parallelly fabricated by ultrafast laser pulses on titanium Enzyme-free photoelectrochemical sensing of glucose based on the TiO2/CuO heterojunction Development of space-borne transportable high-finesse Fabry–Pérot cavity and its performance in ultra-stable laser
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1