Thermo-Modulating Container for Protecting Point-of-Care Devices from Extreme Temperatures during Disaster Relief

C. Gamache, M. Rust, G. Kost
{"title":"Thermo-Modulating Container for Protecting Point-of-Care Devices from Extreme Temperatures during Disaster Relief","authors":"C. Gamache, M. Rust, G. Kost","doi":"10.1109/NEBEC.2013.146","DOIUrl":null,"url":null,"abstract":"When a crisis occurs, emergency medical responders must often operate outside of a hospital setting without basic resources such as electricity. As a result, they rely on point-of-care (POC) testing devices, which are designed to be portable for monitoring critical parameters such as blood gases and glucose levels. Unfortunately, POC devices often have narrow operating ranges, with typical temperature limits within ±10°C of room temperature. This presents significant challenges to the efficiency of the medical response effort since environmental temperatures can vary widely as a function of geography and seasonal weather patterns. To address this issue, a thermo-modulating container is being developed to protect POC devices from extreme temperatures during crisis care situations.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

When a crisis occurs, emergency medical responders must often operate outside of a hospital setting without basic resources such as electricity. As a result, they rely on point-of-care (POC) testing devices, which are designed to be portable for monitoring critical parameters such as blood gases and glucose levels. Unfortunately, POC devices often have narrow operating ranges, with typical temperature limits within ±10°C of room temperature. This presents significant challenges to the efficiency of the medical response effort since environmental temperatures can vary widely as a function of geography and seasonal weather patterns. To address this issue, a thermo-modulating container is being developed to protect POC devices from extreme temperatures during crisis care situations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于在救灾期间保护护理点设备免受极端温度影响的温度调节容器
当危机发生时,紧急医疗救援人员通常必须在没有电力等基本资源的医院环境外工作。因此,他们依赖于护理点(POC)测试设备,这些设备被设计为便携式,用于监测血气和血糖水平等关键参数。不幸的是,POC器件通常具有狭窄的工作范围,典型的温度限制在室温的±10°C内。这对医疗应对工作的效率提出了重大挑战,因为环境温度可能随着地理和季节性天气模式的变化而变化很大。为了解决这个问题,正在开发一种热调节容器,以保护POC设备在危机护理情况下免受极端温度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison between T2 Relaxation Time and Storage Modulus for Agarose Gel The Electroencephalographic Response during a Driving Process: Normal Driving, Turning and Collision Biocompatibility of CaO-Na2O-SiO2/TiO2 Glass Ceramic Scaffolds for Orthopaedic Applications Improvement on Dental Ceramics Using Microwave Sintering Influence of Eccentric Loading and Size of Implant Fixture on the Stress Distribution in the Implant
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1