Short term load forecasting of Eid Al Fitr holiday by using interval Type-2 Fuzzy Inference System (Case study: Electrical system of Java Bali in Indonesia)

Jamaaluddin, I. Robandi
{"title":"Short term load forecasting of Eid Al Fitr holiday by using interval Type-2 Fuzzy Inference System (Case study: Electrical system of Java Bali in Indonesia)","authors":"Jamaaluddin, I. Robandi","doi":"10.1109/TENCONSPRING.2016.7519411","DOIUrl":null,"url":null,"abstract":"Holiday of Eid Al Fitr causing decreased demand of electrical energy until 28.66% in case of Java Bali electricity system in Indonesia. The reduction of electrical demand needs to be known because it related to the efficiency of generation power system. Forecasting methods used in this research is IT-2 FIS. By analyzing the peak load on the day and 4 days before Eid Al Fitr in the previous year continued analysis by using IT-2 FIS will be obtained at the peak load forecasting Eid Al-Fitr in the coming year. The accuracy of this method is shown with the average of error value in 2012, 2013 and 2014 amounting to 0,2431%. This value is better than using the IT-1 FIS which has a value of error amounting to 0.3026%. The research concluded that IT-2 FIS has a value of error smaller than IT-1 FIS.","PeriodicalId":166275,"journal":{"name":"2016 IEEE Region 10 Symposium (TENSYMP)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Region 10 Symposium (TENSYMP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCONSPRING.2016.7519411","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

Holiday of Eid Al Fitr causing decreased demand of electrical energy until 28.66% in case of Java Bali electricity system in Indonesia. The reduction of electrical demand needs to be known because it related to the efficiency of generation power system. Forecasting methods used in this research is IT-2 FIS. By analyzing the peak load on the day and 4 days before Eid Al Fitr in the previous year continued analysis by using IT-2 FIS will be obtained at the peak load forecasting Eid Al-Fitr in the coming year. The accuracy of this method is shown with the average of error value in 2012, 2013 and 2014 amounting to 0,2431%. This value is better than using the IT-1 FIS which has a value of error amounting to 0.3026%. The research concluded that IT-2 FIS has a value of error smaller than IT-1 FIS.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于区间2型模糊推理系统的开斋节短期负荷预测(以印尼爪哇巴厘岛电力系统为例)
开斋节假期导致印尼爪哇巴厘岛电力系统的电力需求下降至28.66%。电力需求的减少需要了解,因为它关系到发电系统的效率。本研究采用的预测方法是it - 2fis。通过对上一年度开斋节当天及开斋节前4天的峰值负荷进行分析,利用IT-2 FIS进行继续分析,得到来年开斋节的峰值负荷预测。2012年、2013年和2014年的误差值平均值为0.2431%,表明了该方法的准确性。这个值比使用IT-1 FIS要好,后者的误差值为0.3026%。研究结果表明,IT-2 FIS的误差值小于IT-1 FIS。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Interaction techniques using head gaze for virtual reality Tree-based protocol for ad hoc networks constructed with data transmission modems Formal reliability analysis of protective systems in smart grids Comparative analysis of PCA and KPCA on paddy growth stages classification Short term load forecasting of Eid Al Fitr holiday by using interval Type-2 Fuzzy Inference System (Case study: Electrical system of Java Bali in Indonesia)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1