A reference system for on-site calibration of high-voltage revenue metering systems

G. Rietveld, Martin Fransen, N. Blanc, E. Houtzager, E. So
{"title":"A reference system for on-site calibration of high-voltage revenue metering systems","authors":"G. Rietveld, Martin Fransen, N. Blanc, E. Houtzager, E. So","doi":"10.1109/CPEM.2014.6898430","DOIUrl":null,"url":null,"abstract":"A reference system for on-site calibration and validation of revenue metering systems is realized. The system consists of a three-phase power meter and high-accuracy current and voltage transformers (CTs and VTs). Measurements can be made up to 150 kV (system voltage) and line currents up to 5000 A. The power meter, the CTs, and the VTs were all calibrated. Based on the excellent results of the calibration of these components it is possible to predict the full system performance with an uncertainty of less than 100 μW/VA. This estimation was verified with a full system validation, showing that the system is much more accurate than required and that detrimental effects to the accuracy are well understood.","PeriodicalId":256575,"journal":{"name":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2014.6898430","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A reference system for on-site calibration and validation of revenue metering systems is realized. The system consists of a three-phase power meter and high-accuracy current and voltage transformers (CTs and VTs). Measurements can be made up to 150 kV (system voltage) and line currents up to 5000 A. The power meter, the CTs, and the VTs were all calibrated. Based on the excellent results of the calibration of these components it is possible to predict the full system performance with an uncertainty of less than 100 μW/VA. This estimation was verified with a full system validation, showing that the system is much more accurate than required and that detrimental effects to the accuracy are well understood.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于现场校准高压收入计量系统的参考系统
实现了税收计量系统现场校准和验证的参考系统。该系统由三相功率计和高精度电流和电压互感器(ct和vt)组成。可以测量高达150千伏(系统电压)和高达5000 A的线路电流。功率计、ct和vt都经过校准。基于这些组件的出色校准结果,可以以小于100 μW/VA的不确定度预测系统的全部性能。这个估计是通过一个完整的系统验证来验证的,表明系统比要求的要准确得多,并且对准确性的有害影响是很容易理解的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stability tests of electronic calibration units Dynamic range improvement of THz spectroscopy Realization of a traceable power quality calibration facility in full accordance with the IEC 61000-4-30 standard Uncertainty of communication signals measurement Determination of the Planck constant at the national institute of Standards and Technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1