{"title":"RANCANG BANGUN SISTEM PENGHITUNGAN HEART RATE MENGGUNAKAN SENSOR FINGER","authors":"Ria Eksaktania, Tri Rijanto, Elly Indahwati","doi":"10.33752/reaktom.v4i2.1247","DOIUrl":null,"url":null,"abstract":"Making heart rate module aims to obtain information module accuracy compared to standard gauge (Pulse Oxymetri). Work system which used using finger and sensor-based Arduino Uno which results are displayed on the LCD. This research uses the method by means of comparing the results of calculating heart rate on the module with the standard gauge (pulse oxymetri) conducted in 5 respondents, each of the respondents was conducted 5 times of measurement. The measurement is done by way of a coexisting between module and checklists (pulse oxymetri) on the index finger of the right and left using the finger sensor. The results of this study showed this tool be eligible to use the benchmarking measurement using Pulse with Oxymetri as much as 5 times by 5 respondents with an average error of results of 0.38%.","PeriodicalId":158977,"journal":{"name":"Reaktom : Rekayasa Keteknikan dan Optimasi","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reaktom : Rekayasa Keteknikan dan Optimasi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33752/reaktom.v4i2.1247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Making heart rate module aims to obtain information module accuracy compared to standard gauge (Pulse Oxymetri). Work system which used using finger and sensor-based Arduino Uno which results are displayed on the LCD. This research uses the method by means of comparing the results of calculating heart rate on the module with the standard gauge (pulse oxymetri) conducted in 5 respondents, each of the respondents was conducted 5 times of measurement. The measurement is done by way of a coexisting between module and checklists (pulse oxymetri) on the index finger of the right and left using the finger sensor. The results of this study showed this tool be eligible to use the benchmarking measurement using Pulse with Oxymetri as much as 5 times by 5 respondents with an average error of results of 0.38%.
制作心率模块的目的是获得与标准仪表(脉搏氧计)相比的信息模块精度。工作系统使用手指和基于传感器的Arduino Uno,其结果显示在LCD上。本研究采用的方法是将模块上计算心率的结果与对5名被调查者进行的标准测量(脉搏氧计)进行比较,每位被调查者进行5次测量。测量是通过模块和使用手指传感器的左、右食指上的检查表(脉搏氧计)共存的方式完成的。本研究的结果表明,该工具符合使用Pulse with Oxymetri多达5次的基准测量条件,平均误差为0.38%。