Opto Electronic Technique for Detection of Corona Discharges in Air and Oil

Nageshwar Rao Burjupati, D. K. Puhan, Rajat Sharma
{"title":"Opto Electronic Technique for Detection of Corona Discharges in Air and Oil","authors":"Nageshwar Rao Burjupati, D. K. Puhan, Rajat Sharma","doi":"10.1109/EIC43217.2019.9046549","DOIUrl":null,"url":null,"abstract":"A study was undertaken in the laboratory of CPRI to understand the detection capability of corona/partial discharges in air and oil medium using opto electronic technique. The experimental investigations were carried out in a high pressure test chamber fitted with high voltage bushing, electrode arrangement with a moving seal, view ports, gas inlets and outlets. PD measuring system consisted of ac high voltage test setup, fluorescent optical fiber, normal optical fiber, fiber adaptor, photomultiplier tube and picoscope for detection of discharges by optical method. Simultaneously the discharges were also detected by electrical method using the conventional system consisting of a high voltage ac source, coupling capacitor cum standard capacitive voltage divider, PD detection unit and test cell. The studies were conducted both in air & oil under uniform and non-uniform electric fields using point plane electrode geometry. The electrode gap distance is varied from 5 mm to 30 mm. The response of different colored fluorescent optical fiber was studied. The results are presented and discussed.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046549","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

A study was undertaken in the laboratory of CPRI to understand the detection capability of corona/partial discharges in air and oil medium using opto electronic technique. The experimental investigations were carried out in a high pressure test chamber fitted with high voltage bushing, electrode arrangement with a moving seal, view ports, gas inlets and outlets. PD measuring system consisted of ac high voltage test setup, fluorescent optical fiber, normal optical fiber, fiber adaptor, photomultiplier tube and picoscope for detection of discharges by optical method. Simultaneously the discharges were also detected by electrical method using the conventional system consisting of a high voltage ac source, coupling capacitor cum standard capacitive voltage divider, PD detection unit and test cell. The studies were conducted both in air & oil under uniform and non-uniform electric fields using point plane electrode geometry. The electrode gap distance is varied from 5 mm to 30 mm. The response of different colored fluorescent optical fiber was studied. The results are presented and discussed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
空气和油中电晕放电的光电检测技术
在CPRI实验室开展了利用光电技术检测空气和油介质中电晕/局部放电的能力的研究。实验研究是在一个高压试验室内进行的,该试验室内装有高压套管,电极布置有移动密封,观察口,气体入口和出口。PD测量系统由交流高压试验装置、荧光光纤、普通光纤、光纤适配器、光电倍增管和光法检测放电的微型镜组成。同时,采用由高压交流电源、耦合电容器和标准电容分压器、PD检测单元和测试单元组成的常规系统,采用电方法对放电进行检测。采用点平面电极几何方法对均匀电场和非均匀电场下的空气和油进行了研究。电极间隙距离从5mm到30mm不等。研究了不同颜色荧光光纤的响应。给出了实验结果并进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diagnostic Testing of Power Cable Insulation For Reliable Smart Grid Operation Investigation of the Thickness Effect on DC Breakdown Strength for HVDC Flexible Cable Insulation Associated with Space Charge Classification of Insulating Liquids Thermal Treatment Using Infrared Spectroscopy and Multivariate Statistical Method Study on the Ageing Characteristics of Persea Americana Oil as an Alternative Transformer Insulation oil Evaluation of Nano-Composite XLPE Compound on Accelerated Aging Cable Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1