Effect of premolar extraction on mandibular rotation

Deepak Chandra, Rohit Khanna, S. Verma, R. Maurya, K. Srivastava, T. Tikku
{"title":"Effect of premolar extraction on mandibular rotation","authors":"Deepak Chandra, Rohit Khanna, S. Verma, R. Maurya, K. Srivastava, T. Tikku","doi":"10.18231/j.ijodr.2022.046","DOIUrl":null,"url":null,"abstract":"Various types of appliances have been tried by the Orthodontists for the fixed orthodontic treatment. Irrespective of the appliance used the main goal of retraction of anterior teeth in extraction cases is to keep the vertical dimension stable so as not to allow downward and backward rotation of mandible. The aim of this study was to compare changes in mandibular rotation following fixed orthodontic treatment on subjects who have undergone extraction of all first premolars. Pre and post treatment lateral cephalogram of 25 subjects were taken (13 females and 12 males), aged 18-25 years and the tracings were done using Nemoceph software. Parameters assessed were facial height (anterior and posterior), mandibular plane angle (FMA & SN-GoGn), and Jaraback ratio. Student t-test was used to make statistical comparison. Mean difference of SN-GoGn(0.15 ±0.07), FMA(0.23 ±0.52), Anterior facial height(0.18±0.01) and posterior height(0.45±0.01) and Jaraback ratio(0.47±0.32) did not show statistically significant difference between pre and post treatment. Mandibular plane did not alter during treatment. When adequate mechanics is followed during treatment desirable treatment outcome with insignificant alteration of mandibular plane can be achieved.","PeriodicalId":269485,"journal":{"name":"IP Indian Journal of Orthodontics and Dentofacial Research","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IP Indian Journal of Orthodontics and Dentofacial Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18231/j.ijodr.2022.046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Various types of appliances have been tried by the Orthodontists for the fixed orthodontic treatment. Irrespective of the appliance used the main goal of retraction of anterior teeth in extraction cases is to keep the vertical dimension stable so as not to allow downward and backward rotation of mandible. The aim of this study was to compare changes in mandibular rotation following fixed orthodontic treatment on subjects who have undergone extraction of all first premolars. Pre and post treatment lateral cephalogram of 25 subjects were taken (13 females and 12 males), aged 18-25 years and the tracings were done using Nemoceph software. Parameters assessed were facial height (anterior and posterior), mandibular plane angle (FMA & SN-GoGn), and Jaraback ratio. Student t-test was used to make statistical comparison. Mean difference of SN-GoGn(0.15 ±0.07), FMA(0.23 ±0.52), Anterior facial height(0.18±0.01) and posterior height(0.45±0.01) and Jaraback ratio(0.47±0.32) did not show statistically significant difference between pre and post treatment. Mandibular plane did not alter during treatment. When adequate mechanics is followed during treatment desirable treatment outcome with insignificant alteration of mandibular plane can be achieved.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
前磨牙拔除对下颌旋转的影响
正畸医生已经尝试了各种类型的矫治器用于固定正畸治疗。无论使用何种矫治器,拔牙时前牙后缩的主要目的是保持垂直尺寸稳定,以免下颌骨向下和向后旋转。本研究的目的是比较固定正畸治疗后下颌旋转的变化,受试者已接受拔除所有第一前磨牙。采用Nemoceph软件对25名年龄在18-25岁的受试者(女性13名,男性12名)进行治疗前后侧位脑电图追踪。评估的参数包括面部高度(前后)、下颌平面角(FMA & SN-GoGn)和Jaraback比值。采用学生t检验进行统计学比较。治疗前后SN-GoGn(0.15±0.07)、FMA(0.23±0.52)、前脸高(0.18±0.01)、后脸高(0.45±0.01)、Jaraback比值(0.47±0.32)的平均差异无统计学意义。治疗期间下颌平面未发生改变。如果在治疗过程中遵循适当的力学方法,可以获得理想的治疗效果,且下颌平面的改变不大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Management of skeletal Class III malocclusion using two-phase therapy in young patient - A case report CBCT: The third eye in orthodontics Comparison between two types of grids for placement of mini-screw implant in posterior maxillary segment Evaluation of surface-modified orthodontic brackets with silver nanoparticles and its influence on bacterial inhibition – An in vitro study Deep bite -An insight
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1