Depth registration of VSP DAS fiber

A. Gordon, D. Lawton, K. Hall, B. Freifeld, T. Daley, P. Cook
{"title":"Depth registration of VSP DAS fiber","authors":"A. Gordon, D. Lawton, K. Hall, B. Freifeld, T. Daley, P. Cook","doi":"10.1190/SEGAM2018-2998408.1","DOIUrl":null,"url":null,"abstract":"As part of the continuous monitoring program implemented at the CO2 injection site developed by Containment and Monitoring Institute, two Vertical Seismic Profiles (VSP) surveys were acquired at the Field Research Station (FRS) in Newell County, Alberta, Canada. The surveys were recorded with two different receiver types; a 24-level 3C geophone array and an integrated fibre optic cable, both Distributed Acoustic Sensing (DAS) and Distributed Temperature Sensing (DTS). A calibration step is necessary to register the precise depth of the DAS traces acquired with the straight fibre optic cable. This calibration consisted on two approaches; a cross-correlation based method and a time difference analysis between the DAS and geophone data. The cross-correlation results indicate an accurate depth registration of the DAS data with respect to the geophone data. A difference of 1 m was obtained for the straight fibre raw data. While the time difference analysis shows a similar result, a difference of 1.25 m for the straight cable. Furthermore, the DAS data was converted to geophone equivalent values through integration for comparison and a more accurate result was obtained for l the DAS data after the calibration workflow. In addition, a synthetic seismogram was generated and compared with corridor stacks obtained from a zero-offset DAS and geophone data processing.","PeriodicalId":158800,"journal":{"name":"SEG Technical Program Expanded Abstracts 2018","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEG Technical Program Expanded Abstracts 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1190/SEGAM2018-2998408.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

As part of the continuous monitoring program implemented at the CO2 injection site developed by Containment and Monitoring Institute, two Vertical Seismic Profiles (VSP) surveys were acquired at the Field Research Station (FRS) in Newell County, Alberta, Canada. The surveys were recorded with two different receiver types; a 24-level 3C geophone array and an integrated fibre optic cable, both Distributed Acoustic Sensing (DAS) and Distributed Temperature Sensing (DTS). A calibration step is necessary to register the precise depth of the DAS traces acquired with the straight fibre optic cable. This calibration consisted on two approaches; a cross-correlation based method and a time difference analysis between the DAS and geophone data. The cross-correlation results indicate an accurate depth registration of the DAS data with respect to the geophone data. A difference of 1 m was obtained for the straight fibre raw data. While the time difference analysis shows a similar result, a difference of 1.25 m for the straight cable. Furthermore, the DAS data was converted to geophone equivalent values through integration for comparison and a more accurate result was obtained for l the DAS data after the calibration workflow. In addition, a synthetic seismogram was generated and compared with corridor stacks obtained from a zero-offset DAS and geophone data processing.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
VSP DAS光纤的深度配准
作为遏制与监测研究所在二氧化碳注入现场实施的连续监测计划的一部分,在加拿大阿尔伯塔省Newell县的现场研究站(FRS)获得了两个垂直地震剖面(VSP)调查数据。调查记录了两种不同类型的接收者;一个24级3C检波器阵列和集成光纤电缆,分布式声学传感(DAS)和分布式温度传感(DTS)。校准步骤是必要的,以记录用直光纤电缆获得的DAS走线的精确深度。该校准包括两种方法;基于互相关的方法和DAS与检波器数据的时差分析。相互关结果表明DAS数据相对于检波器数据的深度配准是准确的。直纤维原始数据的差异为1 m。而时差分析显示了类似的结果,直线电缆的时差为1.25 m。将DAS数据通过积分转换为检波器等效值进行比较,通过标定流程得到了更准确的DAS数据。此外,生成了合成地震记录,并与零偏移DAS和检波器数据处理获得的走廊叠加进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Causality-constrained model-independent joint migration inversion Viscoacoustic forward-modeling method for irregular surface topography based on a second-order viscoacoustic quasidifferential equation without memory variables Influence of the internal geometry on the elastic properties of materials using 3D printing of computer-generated random microstructures Combining 3D HR and OBC datasets to increase bandwidth, signal-to-noise and resolution Identification and evaluation of groundwater resources for small rural and aboriginal communities in Chaco, Argentina
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1