Improvement of grid-connected inverter systems with PR controllers under the unbalanced and distorted grid voltage

Jong-Kyu Kim, Jong-Hyun Lee, Hea-Gwang Jeong, Kyo-Beum Lee
{"title":"Improvement of grid-connected inverter systems with PR controllers under the unbalanced and distorted grid voltage","authors":"Jong-Kyu Kim, Jong-Hyun Lee, Hea-Gwang Jeong, Kyo-Beum Lee","doi":"10.1109/IPEMC.2012.6258998","DOIUrl":null,"url":null,"abstract":"This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition as well as it can compensate the low-order harmonics of the output currents due to the distortion of grid voltage. To reduce the power ripple, the proposed method replaces the four conventional PI controllers with two PR controllers in the stationary frame. PR controllers can implement the compensation of selective harmonic without excessive computational requirements; the use of these controllers simplifies the method. The simulation results agree well with the theoretical analysis.","PeriodicalId":236136,"journal":{"name":"Proceedings of The 7th International Power Electronics and Motion Control Conference","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of The 7th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2012.6258998","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition as well as it can compensate the low-order harmonics of the output currents due to the distortion of grid voltage. To reduce the power ripple, the proposed method replaces the four conventional PI controllers with two PR controllers in the stationary frame. PR controllers can implement the compensation of selective harmonic without excessive computational requirements; the use of these controllers simplifies the method. The simulation results agree well with the theoretical analysis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于PR控制器的并网逆变系统在电网电压不平衡和畸变下的改进
提出了一种电网电压不平衡和畸变情况下并网逆变器系统的控制方法。该方法不仅可以有效地抑制不平衡状态下产生的功率纹波,而且可以补偿因电网电压畸变而产生的输出电流的低次谐波。为了减小功率纹波,该方法在固定帧中用两个PR控制器取代了传统的四个PI控制器。PR控制器可以在不需要过多计算量的情况下实现选择性谐波补偿;这些控制器的使用简化了方法。仿真结果与理论分析吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Tri-state boost PFC converter with high input power factor Application and performance of a multilevel cascaded H-bridge converter on Static Var Generator Optimum sizing of non-grid-connected wind power system incorporating battery-exchange stations Real time selective harmonic minimization for multilevel inverters using genetic algorithm and artificial neural network angle generation Stability analysis of matrix converter with constant power loads and LC input filter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1