Toward real-time detection of critical contingency of large power systems

H. Chiang, Wang Lei
{"title":"Toward real-time detection of critical contingency of large power systems","authors":"H. Chiang, Wang Lei","doi":"10.1109/PESMG.2013.6672366","DOIUrl":null,"url":null,"abstract":"On-line Transient Stability Assessment (TSA) program can fast identify a list of critical contingencies. A real-time critical contingency (RTCC) detection system is to detect, on the basis of the real-time measurements provided by PMUs and the list of critical contingencies, the occurrence of a critical contingency is presented. The RTCC detection system is composed of five detectors. Each of them is designed and placed in a sequential order so as to achieve absolute capture of the occurrence of critical contingencies. The system has been evaluated in 2 test systems and one large-scale power systems with very promising results. The effectiveness of the developed critical contingency detection system is evaluated on 96 contingencies of a 10-machine, 39-bus power system, on 108 contingencies of a 50-generator, 145-bus power system and on 4588 contingencies of a 313-machine, 1648-bus power system.","PeriodicalId":433870,"journal":{"name":"2013 IEEE Power & Energy Society General Meeting","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESMG.2013.6672366","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

On-line Transient Stability Assessment (TSA) program can fast identify a list of critical contingencies. A real-time critical contingency (RTCC) detection system is to detect, on the basis of the real-time measurements provided by PMUs and the list of critical contingencies, the occurrence of a critical contingency is presented. The RTCC detection system is composed of five detectors. Each of them is designed and placed in a sequential order so as to achieve absolute capture of the occurrence of critical contingencies. The system has been evaluated in 2 test systems and one large-scale power systems with very promising results. The effectiveness of the developed critical contingency detection system is evaluated on 96 contingencies of a 10-machine, 39-bus power system, on 108 contingencies of a 50-generator, 145-bus power system and on 4588 contingencies of a 313-machine, 1648-bus power system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
面向大型电力系统关键事故的实时检测
在线暂态稳定评估(TSA)程序可以快速识别一系列重大突发事件。实时关键突发事件(RTCC)检测系统是根据pmu提供的实时测量数据和关键突发事件列表,对关键突发事件的发生进行检测。RTCC检测系统由5个检测器组成。它们中的每一个都是按顺序设计和放置的,以便实现对关键偶然事件发生的绝对捕获。该系统已在2个试验系统和1个大型电力系统中进行了评估,取得了良好的效果。所开发的关键突发事件检测系统的有效性分别在10台发电机39母线电力系统的96个突发事件、50台发电机145母线电力系统的108个突发事件和313台发电机1648母线电力系统的4588个突发事件上进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characterizing statistical bounds on aggregated demand-based primary frequency control SGSim: A unified smart grid simulator FIDVR events analysis part 1 Solid state transformer in the future smart electrical system Challenges for special protection systems in the Chilean electricity market
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1