Amplitude calibration of quartz tuning fork (QTF) force sensor with an atomic force microscope

Danish Hussain, Hao Zhang, Jianmin Song, Wen Yongbing, Xianghe Meng, F. Xinjian, Hui Xie
{"title":"Amplitude calibration of quartz tuning fork (QTF) force sensor with an atomic force microscope","authors":"Danish Hussain, Hao Zhang, Jianmin Song, Wen Yongbing, Xianghe Meng, F. Xinjian, Hui Xie","doi":"10.1109/NANO.2017.8117406","DOIUrl":null,"url":null,"abstract":"Amplitude calibration of the quartz tuning fork (QTF) sensor includes the measurement of the sensitivity factor (αTF). We propose, AFM based methods (cantilever tracking and z-servo tracking of the QTF's amplitude of vibration) to determine the sensitivity factor of the QTF. The QTF is mounted on a xyz-scanner of the AFM and a soft AFM probe is approached on the apex of a tine of the QTF by driving the z-servo and using the normal deflection voltage (Vtb) of position sensitive detector (PSD) as feedback signal. Once the tip contacts the tine, servo is switched off. QTF is electrically excited with a sinusoidal signal from OC4 (Nanonis) and amplitude of the QTF's output at transimpedance amplifier (Vtf) and amplitude of VTB (Vp) is measured by individual lock-in amplifiers which are internally synchronized to the phase of the excitation signal of the QTF. Before, the measurements optical lever is calibrated. By relating the both voltages (Vp & Vtf), sensitivity factor of the QTF (αTF) is determined. In the second approach, after the tip contacts the tine, the z-servo is switched off firstly, then the feedback signal is switched to Vp and frequency sweep for the QTF, Vtb as well as z-servo are started, instantaneously. To keep the Vp at set-point the feedback control moves the z-servo to track the vibration amplitude of the QTF and thus the distance traveled by the z-servo (Δζ) during sweep is equal to the fork's amplitude of vibration (ΔxTF). αtf is determined by relating Δz and VTF. Both approaches can be non-destructively applied for QTF sensor calibration. AFM imaging of the AFM calibration grating TGZ1 (from NT-MDT Russia) has been performed with a calibrated QTF sensor.","PeriodicalId":292399,"journal":{"name":"2017 IEEE 17th International Conference on Nanotechnology (IEEE-NANO)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 17th International Conference on Nanotechnology (IEEE-NANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NANO.2017.8117406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Amplitude calibration of the quartz tuning fork (QTF) sensor includes the measurement of the sensitivity factor (αTF). We propose, AFM based methods (cantilever tracking and z-servo tracking of the QTF's amplitude of vibration) to determine the sensitivity factor of the QTF. The QTF is mounted on a xyz-scanner of the AFM and a soft AFM probe is approached on the apex of a tine of the QTF by driving the z-servo and using the normal deflection voltage (Vtb) of position sensitive detector (PSD) as feedback signal. Once the tip contacts the tine, servo is switched off. QTF is electrically excited with a sinusoidal signal from OC4 (Nanonis) and amplitude of the QTF's output at transimpedance amplifier (Vtf) and amplitude of VTB (Vp) is measured by individual lock-in amplifiers which are internally synchronized to the phase of the excitation signal of the QTF. Before, the measurements optical lever is calibrated. By relating the both voltages (Vp & Vtf), sensitivity factor of the QTF (αTF) is determined. In the second approach, after the tip contacts the tine, the z-servo is switched off firstly, then the feedback signal is switched to Vp and frequency sweep for the QTF, Vtb as well as z-servo are started, instantaneously. To keep the Vp at set-point the feedback control moves the z-servo to track the vibration amplitude of the QTF and thus the distance traveled by the z-servo (Δζ) during sweep is equal to the fork's amplitude of vibration (ΔxTF). αtf is determined by relating Δz and VTF. Both approaches can be non-destructively applied for QTF sensor calibration. AFM imaging of the AFM calibration grating TGZ1 (from NT-MDT Russia) has been performed with a calibrated QTF sensor.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用原子力显微镜标定石英音叉力传感器的振幅
石英音叉(QTF)传感器的振幅校准包括灵敏度因子αTF的测量。我们提出了基于AFM的方法(悬臂跟踪和z伺服跟踪QTF的振动幅度)来确定QTF的灵敏度因子。QTF安装在原子力显微镜的z-扫描仪上,利用位置敏感探测器(PSD)的法向偏转电压(Vtb)作为反馈信号,驱动z-伺服装置接近QTF的一个时间顶点上的软AFM探针。一旦尖端接触到时间,伺服被关闭。QTF由来自OC4 (Nanonis)的正弦信号电激励,在透阻放大器(Vtf)处的QTF输出幅度和VTB的幅度(Vp)由单独的锁相放大器测量,这些锁相放大器内部与QTF激励信号的相位同步。之前,测量光杠杆是校准的。通过两个电压(Vp和Vtf)的关联,确定了QTF的灵敏度因子(αTF)。在第二种方法中,在尖端接触时间后,首先关闭z-伺服,然后将反馈信号切换到Vp,并立即启动QTF, Vtb和z-伺服的扫频。为了使Vp保持在设定点,反馈控制移动z伺服器以跟踪QTF的振动幅度,因此z伺服器(Δζ)在扫描期间行进的距离等于叉子的振动幅度(ΔxTF)。αtf由Δz与VTF的关系确定。两种方法均可无损地用于QTF传感器标定。利用校准后的QTF传感器对AFM校准光栅TGZ1(来自NT-MDT俄罗斯)进行了AFM成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Nanotechnology in multimodal theranostic capsule endoscopy Synthesis of high-strength and electronically conductive triple network gels with self-healing properties by the restraint method Graphene for surface enhanced Raman scattering (SERS) molecular sensors Zero-valent iron based nanoparticles selectively inhibit cancerous cells through mitochondria-mediated autophagy Fabrication and test of a tube shaped e-skin sensor on a colon simulator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1