Effects of Electromyographically-driven Neuromuscular Stimulatio Cycling System on the Lower-Limb of Stroke Survivors

Cheuk-Yan Au, Prabhav Mehra, Kenry W. C. Leung, R. Tong
{"title":"Effects of Electromyographically-driven Neuromuscular Stimulatio Cycling System on the Lower-Limb of Stroke Survivors","authors":"Cheuk-Yan Au, Prabhav Mehra, Kenry W. C. Leung, R. Tong","doi":"10.1109/ICORR.2019.8779541","DOIUrl":null,"url":null,"abstract":"This paper describes the design of an Electromyographically(EMG)-driven Neuromuscular Electrical Stimulation (NMES) cycling system. It utilises real-time EMG from actively participating stroke survivors as feedback control to drive the cycling system for rehabilitation. The user controls the speed of the cycling system using muscle activities of the side affected recorded by EMG electrodes. Additionally, adaptable NMES stimulations; also EMG based, were provided in cyclic pattern to the respective muscle groups in order to improve muscle coordination. The targeted muscle groups used to control the system were the Hamstring (HS), Tibialis Anterior (TA), Quadriceps (QC), Gastrocnemius Lateralis (GL) of the leg on the affected side. Using the system, 20 30-minutes sessions were conducted with chronic stroke survivors (n=10) at frequency of 2–4 sessions per week. Clinical assessment scores, namely FMA_LE, BBS and 6MWT were calculated before the first session and after the completion of 20 sessions. All the assessment scores showed significant improvement after using the system; FMA_LE(P=0.0244), BBS(P=0.0156), 6MWT(P=0.0112), and SI (P=0.0258), showing that the EMG-driven NMES cycling system provides effective rehabilitation for stroke survivors in terms of muscle strength and balance.","PeriodicalId":130415,"journal":{"name":"2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICORR.2019.8779541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes the design of an Electromyographically(EMG)-driven Neuromuscular Electrical Stimulation (NMES) cycling system. It utilises real-time EMG from actively participating stroke survivors as feedback control to drive the cycling system for rehabilitation. The user controls the speed of the cycling system using muscle activities of the side affected recorded by EMG electrodes. Additionally, adaptable NMES stimulations; also EMG based, were provided in cyclic pattern to the respective muscle groups in order to improve muscle coordination. The targeted muscle groups used to control the system were the Hamstring (HS), Tibialis Anterior (TA), Quadriceps (QC), Gastrocnemius Lateralis (GL) of the leg on the affected side. Using the system, 20 30-minutes sessions were conducted with chronic stroke survivors (n=10) at frequency of 2–4 sessions per week. Clinical assessment scores, namely FMA_LE, BBS and 6MWT were calculated before the first session and after the completion of 20 sessions. All the assessment scores showed significant improvement after using the system; FMA_LE(P=0.0244), BBS(P=0.0156), 6MWT(P=0.0112), and SI (P=0.0258), showing that the EMG-driven NMES cycling system provides effective rehabilitation for stroke survivors in terms of muscle strength and balance.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肌电驱动神经肌肉刺激循环系统对中风幸存者下肢的影响
本文介绍了一种肌电图驱动的神经肌肉电刺激循环系统的设计。它利用来自积极参与中风幸存者的实时肌电图作为反馈控制来驱动康复循环系统。使用者利用肌电图电极记录的受影响一侧的肌肉活动来控制循环系统的速度。此外,适应性强的NMES刺激;也基于肌电图,以循环模式提供给各自的肌肉群,以改善肌肉协调。用于控制该系统的目标肌群为患侧腿的腘绳肌(HS)、胫骨前肌(TA)、股四头肌(QC)、腓肠肌外侧肌(GL)。使用该系统,慢性中风幸存者(n=10)以每周2-4次的频率进行20次30分钟的疗程。临床评估评分FMA_LE、BBS和6MWT分别在第一次治疗前和20次治疗结束后计算。使用该系统后,各考核分数均有显著提高;FMA_LE(P=0.0244)、BBS(P=0.0156)、6MWT(P=0.0112)和SI (P=0.0258)表明肌电驱动的NMES循环系统在肌肉力量和平衡方面为脑卒中幸存者提供了有效的康复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Predictive Simulation of Human Walking Augmented by a Powered Ankle Exoskeleton Pattern recognition and direct control home use of a multi-articulating hand prosthesis Feasibility study: Towards Estimation of Fatigue Level in Robot-Assisted Exercise for Cardiac Rehabilitation Performance Evaluation of EEG/EMG Fusion Methods for Motion Classification Texture Discrimination using a Soft Biomimetic Finger for Prosthetic Applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1