Low-Cost, Thermistor Based Respiration Monitor

M. Gupta, H. Qudsi
{"title":"Low-Cost, Thermistor Based Respiration Monitor","authors":"M. Gupta, H. Qudsi","doi":"10.1109/NEBEC.2013.111","DOIUrl":null,"url":null,"abstract":"Respiration rate is a standard physiological measurement taken for monitoring a patient. Existing respiration monitors used in medical centers are too expensive to be used in low-resource environments. We have developed a low-cost respiratory monitor to address this issue. This device calculates a patient's breathing rate by detecting changes in temperature through a thermistor when the patient breathes in a mask. Features of the device include an alarm through a piezoelectric speaker which sounds when the patient stops breathing and a low-battery indicator signal for when the battery powering the device dips below a threshold voltage. The design and implementation involved several different hardware components, as well as software functions. Our initial prototype of our project accomplished our main objectives, and experimental measurements indicate that the device measures a person's respiration rate with relative accuracy.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Respiration rate is a standard physiological measurement taken for monitoring a patient. Existing respiration monitors used in medical centers are too expensive to be used in low-resource environments. We have developed a low-cost respiratory monitor to address this issue. This device calculates a patient's breathing rate by detecting changes in temperature through a thermistor when the patient breathes in a mask. Features of the device include an alarm through a piezoelectric speaker which sounds when the patient stops breathing and a low-battery indicator signal for when the battery powering the device dips below a threshold voltage. The design and implementation involved several different hardware components, as well as software functions. Our initial prototype of our project accomplished our main objectives, and experimental measurements indicate that the device measures a person's respiration rate with relative accuracy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低成本,热敏电阻呼吸监测仪
呼吸率是监测病人的标准生理指标。医疗中心使用的现有呼吸监测器过于昂贵,无法在资源匮乏的环境中使用。我们开发了一种低成本的呼吸监测器来解决这个问题。当患者戴着口罩呼吸时,该设备通过热敏电阻检测温度变化,从而计算出患者的呼吸频率。该设备的特点包括通过压电扬声器发出警报,当患者停止呼吸时发出警报,当设备供电的电池低于阈值电压时发出低电量指示信号。设计和实现涉及几个不同的硬件组件,以及软件功能。我们项目的初始原型完成了我们的主要目标,实验测量表明,该设备测量一个人的呼吸频率相对准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison between T2 Relaxation Time and Storage Modulus for Agarose Gel The Electroencephalographic Response during a Driving Process: Normal Driving, Turning and Collision Biocompatibility of CaO-Na2O-SiO2/TiO2 Glass Ceramic Scaffolds for Orthopaedic Applications Improvement on Dental Ceramics Using Microwave Sintering Influence of Eccentric Loading and Size of Implant Fixture on the Stress Distribution in the Implant
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1