Fault Ride-Through study of PMSG based offshore wind farms during grid faults

H. Dhiman, A. Deshpande
{"title":"Fault Ride-Through study of PMSG based offshore wind farms during grid faults","authors":"H. Dhiman, A. Deshpande","doi":"10.1109/ICPEICES.2016.7853258","DOIUrl":null,"url":null,"abstract":"As the wind power penetration continues to increase in the modern day electrification, the stabilized operation of wind farms interconnected with grids pose an alarming situation. Typically for an asymmetric grid fault, whose probability of occurrence is more than 70%, the voltage and VAR profile of the wind farm gets disturbed thus leading to erroneous operation of wind energy conversion system. LVRT (Low Voltage Ride-Through) requirements for the wind energy conversion systems typically for an offshore based grid interconnection are still under discussion. This paper presents a FACT device based LVRT capability, where the FACT device injects 1pu reactive current in the grid during asymmetric faults as well as symmetric three phase faults.","PeriodicalId":305942,"journal":{"name":"2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPEICES.2016.7853258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

As the wind power penetration continues to increase in the modern day electrification, the stabilized operation of wind farms interconnected with grids pose an alarming situation. Typically for an asymmetric grid fault, whose probability of occurrence is more than 70%, the voltage and VAR profile of the wind farm gets disturbed thus leading to erroneous operation of wind energy conversion system. LVRT (Low Voltage Ride-Through) requirements for the wind energy conversion systems typically for an offshore based grid interconnection are still under discussion. This paper presents a FACT device based LVRT capability, where the FACT device injects 1pu reactive current in the grid during asymmetric faults as well as symmetric three phase faults.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电网故障时基于PMSG的海上风电场故障穿越研究
随着现代电气化进程中风力发电渗透率的不断提高,并网风电场的稳定运行状况令人担忧。典型的不对称电网故障,其发生概率大于70%,会干扰风电场电压和无功分布,导致风能转换系统错误运行。风电转换系统的LVRT(低压穿越)要求通常用于海上电网互连,目前仍在讨论中。本文提出了一种基于FACT装置的LVRT能力,在非对称故障和对称三相故障时,FACT装置向电网注入1pu无功电流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Renewable energy systems for generating electric power: A review A novel design of circular fractal antenna using inset line feed for multiband applications Integrated control of active front steer angle and direct yaw moment using Second Order Sliding Mode technique Voltage differencing buffered amplifier based quadrature oscillator Identification of higher order critically damped systems using relay feedback test
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1