Considerations in unit substation design to optimize reliability and electrical workplace safety

D. Durocher
{"title":"Considerations in unit substation design to optimize reliability and electrical workplace safety","authors":"D. Durocher","doi":"10.1109/CITCON.2010.5470066","DOIUrl":null,"url":null,"abstract":"Many legacy low and medium-voltage unit substations installed today are based upon older designs that took advantage of reduced first cost “opportunities” allowed by existing installation codes and standards. Fast-forward to how these substation designs fair in safety and reliability today, particularly in industrial process applications found in cement, pulp and paper, petroleum & chemical and others, some of the exercised “opportunities” applied in the past begin to look more like liabilities than assets. Legacy engineering decisions once thought to be prudent take on new meanings today, particularly when these decisions are viewed through the lens of emerging new workplace safety standards. The critical issue of addressing destructive arc-flash hazards associated with persons working on or around energized electrical equipment must now be considered. Because traditional substation designs often appeared to involve some compromise regarding both safety and reliability, a design team of a major process industry user took a fresh look at unit substation design. The design review took place in conjunction with construction of a Greenfield plant built in the spring of 2009 in the USA. This paper will review the design limitations of traditional unit substation configurations, offer an overview of the alternatives considered by the Greenfield site project team, and discuss technical and safety validation of the design that was ultimately selected and installed. Economic comparisons to traditional designs, changes in the owner operating and safety procedures for plant personnel as a result of the engineering design changes, and overall design acceptance by operations will also be reviewed in this paper.","PeriodicalId":250209,"journal":{"name":"2010 IEEE-IAS/PCA 52nd Cement Industry Technical Conference","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE-IAS/PCA 52nd Cement Industry Technical Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CITCON.2010.5470066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Many legacy low and medium-voltage unit substations installed today are based upon older designs that took advantage of reduced first cost “opportunities” allowed by existing installation codes and standards. Fast-forward to how these substation designs fair in safety and reliability today, particularly in industrial process applications found in cement, pulp and paper, petroleum & chemical and others, some of the exercised “opportunities” applied in the past begin to look more like liabilities than assets. Legacy engineering decisions once thought to be prudent take on new meanings today, particularly when these decisions are viewed through the lens of emerging new workplace safety standards. The critical issue of addressing destructive arc-flash hazards associated with persons working on or around energized electrical equipment must now be considered. Because traditional substation designs often appeared to involve some compromise regarding both safety and reliability, a design team of a major process industry user took a fresh look at unit substation design. The design review took place in conjunction with construction of a Greenfield plant built in the spring of 2009 in the USA. This paper will review the design limitations of traditional unit substation configurations, offer an overview of the alternatives considered by the Greenfield site project team, and discuss technical and safety validation of the design that was ultimately selected and installed. Economic comparisons to traditional designs, changes in the owner operating and safety procedures for plant personnel as a result of the engineering design changes, and overall design acceptance by operations will also be reviewed in this paper.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
优化单位变电所可靠性和工作场所电气安全的设计考虑
今天安装的许多传统的低压和中压机组变电站都是基于旧的设计,这些设计利用了现有安装规范和标准允许的降低首次成本的“机会”。快进到今天,这些变电站的设计在安全性和可靠性方面是如何公平的,特别是在水泥、纸浆和造纸、石油和化工等工业过程应用中,过去应用的一些实践“机会”开始看起来更像是负债而不是资产。曾经被认为是谨慎的传统工程决策在今天具有了新的意义,特别是当这些决策通过新兴的工作场所安全标准来看待时。现在必须考虑解决与在带电电气设备上或周围工作的人员有关的破坏性电弧闪光危险的关键问题。由于传统的变电站设计往往涉及到安全性和可靠性方面的一些妥协,一个主要过程工业用户的设计团队对单元变电站设计进行了新的审视。设计审查是与2009年春天在美国建造的绿地工厂一起进行的。本文将回顾传统单元变电站配置的设计局限性,概述绿地项目团队考虑的替代方案,并讨论最终选择和安装的设计的技术和安全验证。本文还将审查与传统设计的经济比较,由于工程设计变更而导致的业主操作和工厂人员安全程序的变化,以及运营的总体设计验收。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Successful retrofit upgrade of a Kiln Drive application at Lehigh Cement, York, Pa by replacing existing electromechanical (D.C.) Drive with Direct Hydraulic Drive system Shifting energy performance in U.S. cement production Considerations in unit substation design to optimize reliability and electrical workplace safety Protection principles for electrical motors in the cement industry Operating the worlds largest kiln line
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1