{"title":"Analysis of Rise Time Responses of a Smart Infusion Pump for the Control of Dopamine Drug Flow Rate","authors":"J. Alamelu, Mythili Asaithambi, Swaminathan Ramakrishnan","doi":"10.1109/MeMeA54994.2022.9856447","DOIUrl":null,"url":null,"abstract":"The smart infusion pumps are prominently used to administer drug effectively for the patient. The usage is increased, as the patient safety is critical, and the reduction of medication errors are necessary. The control of drug flow rate in infusion pumps are crucial as it can have substantial impact on patient safety. The implementation of control system model and tuning of the related control parameters are desired. In this paper, an attempt has been made to analyze the rise time (RT) responses of a representative smart infusion pump. The syringe and volumetric administration of Dopamine drug are considered for this study. The examination of the desired target flow rate is accomplished by using different control tuning schemes such as Proportional Integral Derivative (PID) and Internal Mode Controller (IMC). The evaluation of the control strategy is demonstrated with parameters such as RT and settling time (ST). Results show that it is possible to achieve desired RT for the considered infusion conditions by tuning both PID and IMC. The values of RT obtained are 0.215 and 0.383 s respectively. Further, as it is often important to tune RT for patient specific Dopamine administration, the study seems to be relevant for the design of automated drug infusion systems.","PeriodicalId":106228,"journal":{"name":"2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA54994.2022.9856447","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The smart infusion pumps are prominently used to administer drug effectively for the patient. The usage is increased, as the patient safety is critical, and the reduction of medication errors are necessary. The control of drug flow rate in infusion pumps are crucial as it can have substantial impact on patient safety. The implementation of control system model and tuning of the related control parameters are desired. In this paper, an attempt has been made to analyze the rise time (RT) responses of a representative smart infusion pump. The syringe and volumetric administration of Dopamine drug are considered for this study. The examination of the desired target flow rate is accomplished by using different control tuning schemes such as Proportional Integral Derivative (PID) and Internal Mode Controller (IMC). The evaluation of the control strategy is demonstrated with parameters such as RT and settling time (ST). Results show that it is possible to achieve desired RT for the considered infusion conditions by tuning both PID and IMC. The values of RT obtained are 0.215 and 0.383 s respectively. Further, as it is often important to tune RT for patient specific Dopamine administration, the study seems to be relevant for the design of automated drug infusion systems.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
控制多巴胺药物流速的智能输液泵上升时间响应分析
智能输液泵显著地用于有效地给药的病人。由于患者安全至关重要,减少用药错误是必要的,因此使用量增加。输液泵中药物流速的控制对患者的安全有着重要的影响。需要实现控制系统模型和相关控制参数的整定。本文对一种具有代表性的智能输液泵的上升时间响应进行了分析。本研究考虑了多巴胺药物的注射和体积给药。通过使用比例积分导数(PID)和内模控制器(IMC)等不同的控制调谐方案来完成所需目标流量的检查。用RT和沉降时间(ST)等参数对控制策略进行了评价。结果表明,在考虑的输注条件下,通过调整PID和IMC可以实现所需的RT。得到的RT值分别为0.215和0.383 s。此外,由于调整患者特异性多巴胺给药的RT通常很重要,因此该研究似乎与自动药物输注系统的设计有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Time and Frequency domain analysis of APB muscles Abduction in adult dominant hand using surface electromyography signals Comparison of Noise Reduction Techniques for Dysarthric Speech Recognition Effects of ROI positioning on the measurement of engineered muscle tissue contractility with an optical tracking method Atrial Fibrillation Detection by Means of Edge Computing on Wearable Device: A Feasibility Assessment Unraveling the biological meaning of radiomic features
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1