Automated analysis of morpho-functional interbone parameters of the knee based on three dimensional (3D) surface data

Sonja Grothues, Luisa Berger, K. Radermacher
{"title":"Automated analysis of morpho-functional interbone parameters of the knee based on three dimensional (3D) surface data","authors":"Sonja Grothues, Luisa Berger, K. Radermacher","doi":"10.29007/8nb5","DOIUrl":null,"url":null,"abstract":"Interbone parameters of the knee are of relevance in clinical practice, e.g. for the assessment of the functional anatomy of the individual patient. However, respective landmark identification and parameter derivation is mostly done manually. An automated analysis could enable the processing of large datasets, which could again enable the derivation of reference ranges or safe zones for various populations. Hence, the aim of this study was to automate the derivation of interbone parameters from 3D surface data of the knee and to evaluate the method’s robustness against a large dataset.A dataset of 414 knees from patients scheduled for total knee arthroplasty (TKA) was available for the analysis. For each case, knee surface models derived from CT as well as coordinates of the hip and ankle joint centers were available. Eight interbone parameters of the knee were identified in a literature research and an existing framework for morphological analysis of the knee was extended, in order to automatically calculate those parameters.The interbone analysis succeeded for 405 (97.8%) cases. After the exclusion of implausible cases, 373 (90.1%) parameter sets remained for statistical analysis.Differences in methodology, populations, imaging technique etc. complicate the comparison with values from the literature. However, for similar studies a good agreement in parameter values was found.The workflow presented proved robust against a large dataset of knee surface models. In the future, information about the bones’ relative position in the active, weight-bearing situation should be incorporated, in order to assess the impact on knee interbone parameters.","PeriodicalId":385854,"journal":{"name":"EPiC Series in Health Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EPiC Series in Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29007/8nb5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Interbone parameters of the knee are of relevance in clinical practice, e.g. for the assessment of the functional anatomy of the individual patient. However, respective landmark identification and parameter derivation is mostly done manually. An automated analysis could enable the processing of large datasets, which could again enable the derivation of reference ranges or safe zones for various populations. Hence, the aim of this study was to automate the derivation of interbone parameters from 3D surface data of the knee and to evaluate the method’s robustness against a large dataset.A dataset of 414 knees from patients scheduled for total knee arthroplasty (TKA) was available for the analysis. For each case, knee surface models derived from CT as well as coordinates of the hip and ankle joint centers were available. Eight interbone parameters of the knee were identified in a literature research and an existing framework for morphological analysis of the knee was extended, in order to automatically calculate those parameters.The interbone analysis succeeded for 405 (97.8%) cases. After the exclusion of implausible cases, 373 (90.1%) parameter sets remained for statistical analysis.Differences in methodology, populations, imaging technique etc. complicate the comparison with values from the literature. However, for similar studies a good agreement in parameter values was found.The workflow presented proved robust against a large dataset of knee surface models. In the future, information about the bones’ relative position in the active, weight-bearing situation should be incorporated, in order to assess the impact on knee interbone parameters.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于三维(3D)表面数据的膝关节形态功能骨间参数自动分析
膝关节骨间参数在临床实践中具有相关性,例如用于评估个体患者的功能解剖。然而,各自的地标识别和参数推导大多是手工完成的。自动化分析可以使处理大型数据集成为可能,这又可以为各种人口推导出参考范围或安全区。因此,本研究的目的是从膝关节的三维表面数据中自动推导骨间参数,并评估该方法对大型数据集的鲁棒性。来自计划进行全膝关节置换术(TKA)患者的414个膝关节数据集可用于分析。对于每个病例,膝关节表面的CT模型以及髋关节和踝关节中心的坐标都是可用的。通过文献研究,确定了膝关节的8个骨间参数,并对已有的膝关节形态分析框架进行了扩展,实现了这些参数的自动计算。骨间分析成功405例(97.8%)。排除不合理情况后,剩余373组(90.1%)参数集用于统计分析。方法、人口、成像技术等方面的差异使与文献值的比较复杂化。然而,对于类似的研究,在参数值上发现了很好的一致性。该工作流在膝关节表面模型的大型数据集上被证明具有鲁棒性。今后,应纳入活动负重时骨骼相对位置的信息,以评估其对膝关节骨间参数的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Does your approach matter ? Surgeon vs. semi-automated software measured assessment of glenoid retroversion Accuracy Evaluation of Image-Based Virtual Fixtures in Robotic Laminectomy Cloud-Based Three-Dimensional Pattern Analysis and Classification of Proximal Humeral Fractures – A Feasibility Study Automated analysis of morpho-functional interbone parameters of the knee based on three dimensional (3D) surface data
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1