Experimental measurement for turn-off time of RSD switch

L. Liang, Yuehui Yu, Renwei Feng
{"title":"Experimental measurement for turn-off time of RSD switch","authors":"L. Liang, Yuehui Yu, Renwei Feng","doi":"10.1109/IPEMC.2009.5157572","DOIUrl":null,"url":null,"abstract":"The turn-off time of the RSD(reversely switched dynistor) switch is investigated by experiments in this paper. According to its special operating mode, the turn-off criterion of the RSD and a measuring method of the turn-off time are proposed. The measuring platform of the turn-off time is designed and established. The measuring precision is 1.1µs. The experimental results show that the turn-off time of the RSD is in the order from several tens to a hundred microseconds. The increase of the minority lifetime in n-base region makes the turn-off time increase significantly. The turn-off time also increases with enhancing the discharge voltage.","PeriodicalId":375971,"journal":{"name":"2009 IEEE 6th International Power Electronics and Motion Control Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE 6th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2009.5157572","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The turn-off time of the RSD(reversely switched dynistor) switch is investigated by experiments in this paper. According to its special operating mode, the turn-off criterion of the RSD and a measuring method of the turn-off time are proposed. The measuring platform of the turn-off time is designed and established. The measuring precision is 1.1µs. The experimental results show that the turn-off time of the RSD is in the order from several tens to a hundred microseconds. The increase of the minority lifetime in n-base region makes the turn-off time increase significantly. The turn-off time also increases with enhancing the discharge voltage.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
RSD开关关断时间的实验测量
本文通过实验研究了RSD开关的关断时间。根据其特殊的工作方式,提出了RSD的关断判据和关断时间的测量方法。设计并建立了关断时间测量平台。测量精度为1.1µs。实验结果表明,RSD的关断时间在几十到100微秒之间。n基区少数族裔寿命的增加使得关断时间显著增加。关断时间也随放电电压的增大而增大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Study and implementation of a single-stage three-phase AC-DC converter A resonant gate-drive circuit capable of high-frequency and high-efficiency operation Study of multi-level rectifier in high power system based on a novel virtual flux observer Power control strategy of electronic ballast for Metal Halide Lamps Design of a digital control IC of a current source based on a three-phase controlled rectifier
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1