Binary Equilibrium Optimizer Based Weak bus Constrained PMU Placement

P. M. Joshi, H. Verma
{"title":"Binary Equilibrium Optimizer Based Weak bus Constrained PMU Placement","authors":"P. M. Joshi, H. Verma","doi":"10.1109/ETI4.051663.2021.9619191","DOIUrl":null,"url":null,"abstract":"This work proposes weak bus constrained optimal placement of phasor measurement units (PMUs) in standard IEEE systems using binary Equilibrium Optimizer (BEO). The novelty of this work is to place the PMUs on such locations that weak buses are observed with maximum number of PMUs to ascertain full observability and stability of the system. The different combinations for installation of PMUs for other cases are also obtained by BEO. For investigating the effectiveness of the approach, it is tested on different test cases which are IEEE 14 bus, IEEE 30 bus, IEEE 57 bus and IEEE 118 bus systems with different conditions that include consideration of zero injection buses, single PMU outage, weak buses in the systems.","PeriodicalId":129682,"journal":{"name":"2021 Emerging Trends in Industry 4.0 (ETI 4.0)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Emerging Trends in Industry 4.0 (ETI 4.0)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ETI4.051663.2021.9619191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This work proposes weak bus constrained optimal placement of phasor measurement units (PMUs) in standard IEEE systems using binary Equilibrium Optimizer (BEO). The novelty of this work is to place the PMUs on such locations that weak buses are observed with maximum number of PMUs to ascertain full observability and stability of the system. The different combinations for installation of PMUs for other cases are also obtained by BEO. For investigating the effectiveness of the approach, it is tested on different test cases which are IEEE 14 bus, IEEE 30 bus, IEEE 57 bus and IEEE 118 bus systems with different conditions that include consideration of zero injection buses, single PMU outage, weak buses in the systems.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于二元平衡优化器的弱总线约束PMU布局
这项工作提出了弱总线约束下的相量测量单元(pmu)在标准IEEE系统中使用二进制平衡优化器(BEO)的最佳放置。这项工作的新颖之处在于将pmu放置在这样的位置,即弱总线被观察到的pmu数量最大,以确定系统的完全可观察性和稳定性。BEO还获得了其他情况下pmu的不同安装组合。为了验证该方法的有效性,在ieee14总线、ieee30总线、ieee57总线和ieee118总线系统的不同测试用例上进行了测试,测试用例考虑了系统中零注入总线、单PMU停电、弱总线等不同条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Detecting Sybil Attack, Black Hole Attack and DoS Attack in VANET Using RSA Algorithm Real Time Servo Analysis of Non-Linear Conical Tank Level Control using Root Locus Technique Apply Blockchain Technology for Security of IoT Devices A Highly Efficient Intrusion Detection and Packet Tracking Based on Game Theory Approach Logistic Regression Model for Loan Prediction: A Machine Learning Approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1