AvanTomography: A compact module for positron emission mammography

Defne Us, Amalia Moreno-Galera, S. Nazari-Farsani, K. Palovuori, Heikki Kosola, Tiziana Zedda, U. Ruotsalainen
{"title":"AvanTomography: A compact module for positron emission mammography","authors":"Defne Us, Amalia Moreno-Galera, S. Nazari-Farsani, K. Palovuori, Heikki Kosola, Tiziana Zedda, U. Ruotsalainen","doi":"10.1109/MeMeA.2015.7145171","DOIUrl":null,"url":null,"abstract":"In AvanTomography project, a compact, high performance module was developed for axial positron emission mammography, which can be integrated with X-ray mammography. With its axial crystal orientation, AvanTomography can achieve a uniform spatial resolution and eliminate the parallax error by unambiguously detecting the location of the positron annihilation. Compact design of the module enables a cost and space efficient system for breast screening. Various configurations, plate or full ring, can be obtained by using multiple modules, allowing the screening of axillary and mammary regions with a single scanner position. In this project, a 6-module system was constructed and tested with a 22Na point source. Energy calibration was performed and initial measurements for energy resolution were conducted.","PeriodicalId":277757,"journal":{"name":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2015.7145171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In AvanTomography project, a compact, high performance module was developed for axial positron emission mammography, which can be integrated with X-ray mammography. With its axial crystal orientation, AvanTomography can achieve a uniform spatial resolution and eliminate the parallax error by unambiguously detecting the location of the positron annihilation. Compact design of the module enables a cost and space efficient system for breast screening. Various configurations, plate or full ring, can be obtained by using multiple modules, allowing the screening of axillary and mammary regions with a single scanner position. In this project, a 6-module system was constructed and tested with a 22Na point source. Energy calibration was performed and initial measurements for energy resolution were conducted.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
AvanTomography:一个紧凑的模块,用于正电子发射乳房x线摄影
在AvanTomography项目中,开发了一种紧凑、高性能的轴向正电子发射乳房x线摄影模块,可与x射线乳房x线摄影集成。AvanTomography利用其轴向晶体取向,通过清晰地探测正电子湮灭的位置,实现了均匀的空间分辨率,消除了视差误差。紧凑的设计模块使成本和空间有效的乳房筛查系统。通过使用多个模块,可以获得各种配置,板式或全环形,允许使用单个扫描仪位置对腋窝和乳房区域进行筛查。在本项目中,构建了一个6模块系统,并使用22Na点源进行了测试。进行了能量校准,并进行了能量分辨率的初步测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Needle detection by electro-localization for a needle EMG exam robotic simulator Evaluation of control modes for head motion-based control with motion sensors A novel automatically initialized level set approach based on region correlation for lumbar vertebrae CT image segmentation Smart environments using near-field communication and HTML5 New FEM 3D model for arm-cuff interface simulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1