Determination of blackbody cavity reflectance at 633nm by integrating sphere reflectometer

Jing-hui Wang, Zun-dong Yuan, Yuanyuan Duan, Zeng-lin Liu, Xiao-feng Lu
{"title":"Determination of blackbody cavity reflectance at 633nm by integrating sphere reflectometer","authors":"Jing-hui Wang, Zun-dong Yuan, Yuanyuan Duan, Zeng-lin Liu, Xiao-feng Lu","doi":"10.1109/SICE.2015.7285461","DOIUrl":null,"url":null,"abstract":"The blackbody cavity emissivity is a primary parameter of blackbody source. The measurement of blackbody cavity emissivity could verify the design value of cavity emissivity. A determination of graphite blackbody cavity emissivity by reflectance measurement is presented. The measuring equipment include a He-Ne laser, laser power stabilizer, integrating sphere, Si photoelectric detector, gray reflectance standard sample and Keithley 6485 picoammeter. The preliminary measurement value of graphite blackbody cavity emissivity is 0.99983351.","PeriodicalId":405766,"journal":{"name":"Annual Conference of the Society of Instrument and Control Engineers of Japan","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual Conference of the Society of Instrument and Control Engineers of Japan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2015.7285461","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The blackbody cavity emissivity is a primary parameter of blackbody source. The measurement of blackbody cavity emissivity could verify the design value of cavity emissivity. A determination of graphite blackbody cavity emissivity by reflectance measurement is presented. The measuring equipment include a He-Ne laser, laser power stabilizer, integrating sphere, Si photoelectric detector, gray reflectance standard sample and Keithley 6485 picoammeter. The preliminary measurement value of graphite blackbody cavity emissivity is 0.99983351.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
积分球反射计测定633nm处黑体空腔反射率
黑体空腔辐射率是黑体源的一个重要参数。黑体空腔发射率的测量可以验证空腔发射率的设计值。提出了用反射率法测定石墨黑体空腔发射率的方法。测量设备包括氦氖激光器、激光功率稳定器、积分球、硅光电探测器、灰度反射标准样品和基思利6485皮安计。石墨黑体空腔发射率初步测量值为0.99983351。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On the Sudoku-based Arrangement in Reconfiguring a Large-scale Photovoltaic Array Topology Control for Wireless Sensor Network in Landslide Monitoring Hand motion recognition with postural changes using surface EMG signals Gait state transition by gait training using interactive rhythmic auditory cue in development process of gait rhythm generation disorders Development of a prototype of variable stiffness ion conductive polymer actuator with a shape memory polymer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1