{"title":"[High voltage power station to study the influence of the DC-field with superimposed AC-field on humans (author's transl)].","authors":"G Wiesspeiner, R Waibel","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Due to the great progress in electrical engineering man is exposed to electric fields in a high degree. However, the effect of the electric field has not been definitely cleared up till now. The following parameters are of decisive importance: Field intensity- Frequency-Shape of curve-Boundary conditions. As scientific investigations can only be reproduced and accepted when the experimental conditions are clearly defined, a station meeting these requirements has been developed. It consists of Testing room: Electric screen damping higher than 80 dB-Magnetic screen damping higher than 45 dB-large, cased ceiling electrode. Control room: Same as testing room, but no screening. High voltage generator: a) DC-Voltage 0-20 kV ripple & noise less than 0.01%; b) Alternating voltage 0-300 Vss frequency 5 Hz-50 kHz; c) combination of a) and b).</p>","PeriodicalId":76867,"journal":{"name":"Zentralblatt fur Bakteriologie, Parasitenkunde, Infektionskrankheiten und Hygiene. Erste Abteilung Originale. Reihe B: Hygiene, Betriebshygiene, praventive Medizin","volume":"169 3-4","pages":"337-41"},"PeriodicalIF":0.0000,"publicationDate":"1979-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zentralblatt fur Bakteriologie, Parasitenkunde, Infektionskrankheiten und Hygiene. Erste Abteilung Originale. Reihe B: Hygiene, Betriebshygiene, praventive Medizin","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Due to the great progress in electrical engineering man is exposed to electric fields in a high degree. However, the effect of the electric field has not been definitely cleared up till now. The following parameters are of decisive importance: Field intensity- Frequency-Shape of curve-Boundary conditions. As scientific investigations can only be reproduced and accepted when the experimental conditions are clearly defined, a station meeting these requirements has been developed. It consists of Testing room: Electric screen damping higher than 80 dB-Magnetic screen damping higher than 45 dB-large, cased ceiling electrode. Control room: Same as testing room, but no screening. High voltage generator: a) DC-Voltage 0-20 kV ripple & noise less than 0.01%; b) Alternating voltage 0-300 Vss frequency 5 Hz-50 kHz; c) combination of a) and b).