{"title":"EFFECT OF SOIL DENSITY AND PLUG CHARACTERISTICS ON BEHAVIOR OF SINGLE PIPE PILE EMBEDDED IN COHESIONLESS SOIL AND SUBJECTED TO UPLIFT FORCE","authors":"H. S. Hamadi, H. A. Abdul-Husain","doi":"10.30572/2018/kje/120301","DOIUrl":null,"url":null,"abstract":"It is a significant issue to analyze and understand the pile’s behavior as well as to predict the piles’ capacity exposed to uplifting load when designing a foundation. Experimental model tests have been conducted for a single pile embedded in cohesionless soil and subjected to uplift force. The experimental tests were performed using open-ended steel pipe piles with circular cross-sectional area an outer diameter of 50 mm in steel soil box (0.5*0.5) with four different height (0.30, 0.50 and two with 0.40 m). The tested piles have been embedment with penetration ratios (PR=L/D) of 10. Three different densities (25%, 50% and 75%) have been used to perform the tests. In addition three tests have been made with relative density of 50% to investigate the function the developed soil column inside the pile (soil plug) during installation. The results revealed that the behavior of single piles depends mainly on soil density and the ultimate pull-out capacity of the pile increases with the increasing of the soil relative density and used the data from this tests to presented formula to estimate the IFR and takes the soil state parameter as a qualitative variable. The results showed also that the removing of plugging soil decreases the pile’s pull-out capacity by about 85%. Whilst, using of closed-end or filled with concrete give higher capacity than that of open-end pipe pile by about 33% and 87% respectively.","PeriodicalId":123515,"journal":{"name":"Kufa Journal of Engineering","volume":"128 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kufa Journal of Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30572/2018/kje/120301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

It is a significant issue to analyze and understand the pile’s behavior as well as to predict the piles’ capacity exposed to uplifting load when designing a foundation. Experimental model tests have been conducted for a single pile embedded in cohesionless soil and subjected to uplift force. The experimental tests were performed using open-ended steel pipe piles with circular cross-sectional area an outer diameter of 50 mm in steel soil box (0.5*0.5) with four different height (0.30, 0.50 and two with 0.40 m). The tested piles have been embedment with penetration ratios (PR=L/D) of 10. Three different densities (25%, 50% and 75%) have been used to perform the tests. In addition three tests have been made with relative density of 50% to investigate the function the developed soil column inside the pile (soil plug) during installation. The results revealed that the behavior of single piles depends mainly on soil density and the ultimate pull-out capacity of the pile increases with the increasing of the soil relative density and used the data from this tests to presented formula to estimate the IFR and takes the soil state parameter as a qualitative variable. The results showed also that the removing of plugging soil decreases the pile’s pull-out capacity by about 85%. Whilst, using of closed-end or filled with concrete give higher capacity than that of open-end pipe pile by about 33% and 87% respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
土密度和桩塞特性对无黏性土中单管桩抗拔性能的影响
在基础设计中,分析和理解桩的受力特性,预测桩在上拔荷载作用下的承载力是一个重要的问题。对单桩在无黏性土体中进行了抗拔试验模型试验。试验采用外径为50 mm的圆形截面积钢管桩,在0.5*0.5的钢土箱中进行4个不同高度(0.30、0.50和2个0.40 m)的开孔钢管桩,桩身嵌入比(PR=L/D)为10。试验采用了三种不同的密度(25%、50%和75%)。此外,还进行了3次相对密度为50%的试验,研究了桩内发育的土柱(土塞)在安装过程中的作用。结果表明,单桩的性能主要取决于土密度,桩的极限抗拔能力随土相对密度的增加而增加,并利用本次试验数据,以土状态参数为定性变量,给出了估算IFR的公式。结果还表明,堵土的清除使桩的拔桩能力降低了85%左右。而采用闭端管桩和灌浆管桩的承载力分别比开端管桩高33%和87%左右。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
THE STUDYOF INSULATING PROPERTIES OF REFRACTORY BRICKS PRODUCED USING MELON SEED HUSKSAS POREFORMER BIO-ADSORPTION OF HEAVY METAL ION FROM WATER USING ACTIVATED CARBON EFFECT OF ZIRCONIUM ADDITION ON MICROSTRUCTURE AND PROPERTIES OF PURE TI PRODUCED BY POWDER METALLURGY DEVELOPMENT OF MICROSTRUCTURE, MECHANICAL AND WEAR CHARACTERISTICS OF THE BRASS ALLOY PROCESSED BY ECAP HIGHLY EFFICIENT INVERTER BLOCKS IN QCA TECHNOLOGY
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1