Differential R-to-I conversion circuit for gas sensing in biomedical applications

Zeinab Hijazi, D. Caviglia, H. Chible, M. Valle
{"title":"Differential R-to-I conversion circuit for gas sensing in biomedical applications","authors":"Zeinab Hijazi, D. Caviglia, H. Chible, M. Valle","doi":"10.1109/MECBME.2016.7745412","DOIUrl":null,"url":null,"abstract":"In biomedical engineering specifically gas sensing applications, the concentration of the exhaled gas is converted to a variation in resistance, thus an electronic integrated interface circuit is required to analyze the exhaled gases, which are indications for many diseases. In this paper, a differential resistance to current conversion circuit for Electronic nose (E-nose) breath analyzer is presented. Over an input resistance range of more than 5-decades (500Ω to 100MΩ), a precision, less than 1%, required by novel gas sensing system in portable applications, is preserved. As a result, the proposed circuit obtains high accuracy under simulation. The outputs of the proposed Resistance to Current (R-to-I) conversion circuit achieve a percentage error below 0.25% under environment corners. The reliability of the proposed circuit is also investigated under the effect of process variations. In order to assess the correctness of the proposed architecture, the circuit was compared to similar solutions presented in literature. The proposed architecture attains a worst-case percentage error of 0.05%.","PeriodicalId":430369,"journal":{"name":"2016 3rd Middle East Conference on Biomedical Engineering (MECBME)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 3rd Middle East Conference on Biomedical Engineering (MECBME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECBME.2016.7745412","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In biomedical engineering specifically gas sensing applications, the concentration of the exhaled gas is converted to a variation in resistance, thus an electronic integrated interface circuit is required to analyze the exhaled gases, which are indications for many diseases. In this paper, a differential resistance to current conversion circuit for Electronic nose (E-nose) breath analyzer is presented. Over an input resistance range of more than 5-decades (500Ω to 100MΩ), a precision, less than 1%, required by novel gas sensing system in portable applications, is preserved. As a result, the proposed circuit obtains high accuracy under simulation. The outputs of the proposed Resistance to Current (R-to-I) conversion circuit achieve a percentage error below 0.25% under environment corners. The reliability of the proposed circuit is also investigated under the effect of process variations. In order to assess the correctness of the proposed architecture, the circuit was compared to similar solutions presented in literature. The proposed architecture attains a worst-case percentage error of 0.05%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
差分r - i转换电路,用于生物医学应用中的气体传感
在生物医学工程特别是气体传感应用中,呼出气体的浓度被转换为电阻的变化,因此需要电子集成接口电路来分析呼出气体,这是许多疾病的迹象。本文介绍了一种用于电子鼻呼气分析仪的差分电阻电流转换电路。在超过50年的输入电阻范围内(500Ω至100MΩ),在便携式应用中,新型气体传感系统所需的精度低于1%。仿真结果表明,该电路具有较高的精度。所提出的电流电阻(R-to-I)转换电路的输出在环境角下的百分比误差低于0.25%。在工艺变化的影响下,研究了所提电路的可靠性。为了评估所提出的架构的正确性,将电路与文献中提出的类似解决方案进行了比较。所提出的体系结构的最坏情况百分比误差为0.05%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A comparison of post-processing techniques on the performance of EMG based pattern recognition system for the transradial amputees Design of a multifunctional universal mask for patients On-line optimal design of process noise covariance in nonlinear Kalman Filters: A hemodynamic model application Differential R-to-I conversion circuit for gas sensing in biomedical applications Face Detection with Expression Recognition using Artificial Neural Networks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1