Linear Feedback Controller for D-Statcom in DPG Fault Application

S. Aizam, B. C. Kok, N. Mariun, H. Hizam, N. Wahab
{"title":"Linear Feedback Controller for D-Statcom in DPG Fault Application","authors":"S. Aizam, B. C. Kok, N. Mariun, H. Hizam, N. Wahab","doi":"10.1109/UPEC.2006.367627","DOIUrl":null,"url":null,"abstract":"This paper presents the application of linear feedback controller on distribution static synchronous compensator (D-STATCOM) for mitigating double phase to ground (DPG) fault at the distribution system. The pole placement technique is applied by shifting the existing poles to the new poles locations for fast response compare to the conventional controller. This type of inverter control is very useful in D-STATCOM application which controls the inverter to inject the unbalanced current or voltage or both for mitigating the fault condition that occurs at the distribution system. The controller will give respond to the lines that are affected by the fault and restore the system to its normal conditions. The simulation and design of the controller is done using MATLAB software with Power Blockset Toolbox and SIMULINK","PeriodicalId":184186,"journal":{"name":"Proceedings of the 41st International Universities Power Engineering Conference","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 41st International Universities Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2006.367627","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

This paper presents the application of linear feedback controller on distribution static synchronous compensator (D-STATCOM) for mitigating double phase to ground (DPG) fault at the distribution system. The pole placement technique is applied by shifting the existing poles to the new poles locations for fast response compare to the conventional controller. This type of inverter control is very useful in D-STATCOM application which controls the inverter to inject the unbalanced current or voltage or both for mitigating the fault condition that occurs at the distribution system. The controller will give respond to the lines that are affected by the fault and restore the system to its normal conditions. The simulation and design of the controller is done using MATLAB software with Power Blockset Toolbox and SIMULINK
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
D-Statcom线性反馈控制器在DPG故障中的应用
本文介绍了线性反馈控制器在配电静态同步补偿器(D-STATCOM)上的应用,以减轻配电系统双相接地(DPG)故障。极点放置技术通过将现有极点移动到新的极点位置来实现与传统控制器相比的快速响应。这种类型的逆变器控制在D-STATCOM应用中非常有用,它控制逆变器注入不平衡电流或电压,或两者兼有,以减轻配电系统发生的故障情况。控制器将对受故障影响的线路作出响应,使系统恢复到正常状态。采用MATLAB软件,结合Power Blockset Toolbox和SIMULINK对控制器进行仿真设计
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transient Short-Circuit Behaviour of Distributed Energy Sources and Their Influence on Protection Coordination Using Active Power Filter Based on New Control Strategy to Compensate Power Quality Assessment of DSM Potential in the Governmental Sector in Egypt and its Effect on the National Power System Development A New Method for the Price Determination of the Reactive Power Supply Grid Integration of Wind Farms Using SVC and STATCOM
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1