{"title":"지하수 열원 지중 열교환기의 열적 특성에 관한 실험적 연구","authors":"강경문, 고수성, Myung-Taek Hyun, 임연주","doi":"10.17958/ksmt.21.4.201908.593","DOIUrl":null,"url":null,"abstract":"In order to enhance the utilization of underground heat including underground water, the comparison between the existing high density polyethylene underground heat exchanger and the newly developed metal heat exchanger was conducted to suggest the potential use of geothermal energy corresponding to the geological characteristics of Jeju Island. When the acquired heat of the underground loop system test condition of the KS B 8292 water-water geothermal heat pump unit was compared by installing heat exchanger of HDPE material and the heat exchanger of STS material under the same bore hole condition, the total heat area of the heat exchanger of STS material was about 15% less than HDPE, but the acquired heat was estimated to be about 4 times or more.","PeriodicalId":168106,"journal":{"name":"Journal of the Korean Society of Mechanical Technology","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Society of Mechanical Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17958/ksmt.21.4.201908.593","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In order to enhance the utilization of underground heat including underground water, the comparison between the existing high density polyethylene underground heat exchanger and the newly developed metal heat exchanger was conducted to suggest the potential use of geothermal energy corresponding to the geological characteristics of Jeju Island. When the acquired heat of the underground loop system test condition of the KS B 8292 water-water geothermal heat pump unit was compared by installing heat exchanger of HDPE material and the heat exchanger of STS material under the same bore hole condition, the total heat area of the heat exchanger of STS material was about 15% less than HDPE, but the acquired heat was estimated to be about 4 times or more.
为了提高对包括地下水在内的地下热量的利用,对现有高密度聚乙烯地下换热器与新开发的金属换热器进行了比较,并根据济州岛的地质特征提出了地热能的潜在利用方法。将KS B 8292水-水型地源热泵机组地下回路系统试验工况下安装HDPE材料换热器与STS材料换热器进行比较,在相同钻孔条件下,STS材料换热器的总热面积比HDPE少15%左右,但获得的热量估计约为HDPE的4倍以上。