G. Volkov, V. I. Zaĭtsev, A. Kartashov, N. I. Lahtushko, A. Rupasov, A. S. Shikanov
{"title":"Microsecond Z-pinch as ultrasoft X-ray radiation source","authors":"G. Volkov, V. I. Zaĭtsev, A. Kartashov, N. I. Lahtushko, A. Rupasov, A. S. Shikanov","doi":"10.1051/JP4:2006133158","DOIUrl":null,"url":null,"abstract":"Spectral characteristics of plasma radiation of a gas Z-pinch with a rise time of 1 μs and current amplitude of 250 kA have been measured. The measurements were performed in the range of X-ray energy quanta from 30 eV to 600 eV. A spectrograph with a transmission grating and a polychromator on the basis of multilayer X-ray mirrors served as the diagnostic devices. Absolutely calibrated semiconducting detectors AXUV-5 were taken as the radiation detector in the polychromator. Full pinch radiation loss was measured with a thermocouple calorimeter. The radiation of He-, Li- and Be- like ions has been shown to dominate at the stage of maximum compression of the nitrogen Z-pinch. The results of the spectral measurements were employed for absolute calibration of various X-ray detectors. Some of these calibration results are presented in the work. Using Ne and Ar as the working gases permits us to proceed to measurements in a ≪harder≫ spectral band and to conduct a detailed study of the line radiation polarization degree for He- like ions of the given elements.","PeriodicalId":256101,"journal":{"name":"2004 International Conference on High-Power Particle Beams (BEAMS 2004)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 International Conference on High-Power Particle Beams (BEAMS 2004)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/JP4:2006133158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Spectral characteristics of plasma radiation of a gas Z-pinch with a rise time of 1 μs and current amplitude of 250 kA have been measured. The measurements were performed in the range of X-ray energy quanta from 30 eV to 600 eV. A spectrograph with a transmission grating and a polychromator on the basis of multilayer X-ray mirrors served as the diagnostic devices. Absolutely calibrated semiconducting detectors AXUV-5 were taken as the radiation detector in the polychromator. Full pinch radiation loss was measured with a thermocouple calorimeter. The radiation of He-, Li- and Be- like ions has been shown to dominate at the stage of maximum compression of the nitrogen Z-pinch. The results of the spectral measurements were employed for absolute calibration of various X-ray detectors. Some of these calibration results are presented in the work. Using Ne and Ar as the working gases permits us to proceed to measurements in a ≪harder≫ spectral band and to conduct a detailed study of the line radiation polarization degree for He- like ions of the given elements.