{"title":"Noninvasive diagnosis of carbon monoxide poisoning using Extended Modified Lambert Beer Model","authors":"A. Huong, X. Ngu","doi":"10.1109/ICED.2014.7015811","DOIUrl":null,"url":null,"abstract":"We aim to demonstrate the feasibility of using Extended Modified Lambert Beer model (EMLB) to detect differences in percent mean blood oxyhemoglobin (SmO2) and carboxyhemoglobin (SmCO) saturations between smoking and nonsmoking populations. The value of these parameters is given by those that produced the closest agreement between the EMLB and the measured data optimized using the developed fitting routine. This fitting algorithm used extinction coefficients of light absorbing hemoglobin species in the wavelength range of 520-600 nm as the background information. The reflectance spectroscopy measurement on left thumb of five smokers and four nonsmokers at rest condition revealed percent SmO2 and SmCO with mean value of 81.9 ± 8.8% and 16.2 ± 4.8%, respectively, for smoking population. Meanwhile a higher mean SmO2 of 86.5 ± 1.6% and lower mean SmCO of 11.7 ± 1.6% are observed for nonsmoking individuals. These values are compared to that reported in the literature. This study concluded that the proposed model and fitting strategy is able to detect differences in percent blood saturations of smoking and nonsmoking volunteers, hence potentially be used to clinically detect carbon monoxide poisoning in men.","PeriodicalId":143806,"journal":{"name":"2014 2nd International Conference on Electronic Design (ICED)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 2nd International Conference on Electronic Design (ICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICED.2014.7015811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

We aim to demonstrate the feasibility of using Extended Modified Lambert Beer model (EMLB) to detect differences in percent mean blood oxyhemoglobin (SmO2) and carboxyhemoglobin (SmCO) saturations between smoking and nonsmoking populations. The value of these parameters is given by those that produced the closest agreement between the EMLB and the measured data optimized using the developed fitting routine. This fitting algorithm used extinction coefficients of light absorbing hemoglobin species in the wavelength range of 520-600 nm as the background information. The reflectance spectroscopy measurement on left thumb of five smokers and four nonsmokers at rest condition revealed percent SmO2 and SmCO with mean value of 81.9 ± 8.8% and 16.2 ± 4.8%, respectively, for smoking population. Meanwhile a higher mean SmO2 of 86.5 ± 1.6% and lower mean SmCO of 11.7 ± 1.6% are observed for nonsmoking individuals. These values are compared to that reported in the literature. This study concluded that the proposed model and fitting strategy is able to detect differences in percent blood saturations of smoking and nonsmoking volunteers, hence potentially be used to clinically detect carbon monoxide poisoning in men.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
扩展修正Lambert - Beer模型在一氧化碳中毒诊断中的应用
我们的目的是证明使用扩展修正Lambert Beer模型(EMLB)检测吸烟人群和不吸烟人群之间平均血氧血红蛋白(SmO2)和碳氧血红蛋白(SmCO)饱和度百分比差异的可行性。这些参数的值是由EMLB和使用开发的拟合程序优化的测量数据之间产生最接近一致的值给出的。该拟合算法以520 ~ 600 nm波长范围内的吸光血红蛋白物种消光系数为背景信息。5名吸烟者和4名非吸烟者在休息状态下左手拇指的反射光谱测量显示,吸烟者的SmO2和SmCO百分比平均值分别为81.9±8.8%和16.2±4.8%。与此同时,非吸烟人群的平均SmCO值较高,为86.5±1.6%,平均SmCO值较低,为11.7±1.6%。将这些值与文献报道的值进行比较。这项研究的结论是,所提出的模型和拟合策略能够检测吸烟和不吸烟志愿者血液饱和度百分比的差异,因此有可能用于临床检测男性一氧化碳中毒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A new trimming approach for shunt resistors used in metering applications Taxanomy and overview on cooperative MAC for vehicular ad hoc networks Electrical characterization of USB2 multiplexers/BC1.2 power switches/charging modules for accurate channel simulation Experimental studies of the correlation between fingers bending angle with voltage outputted from GloveMAP Comparison on TiO2 and TaO2 based bipolar resistive switching devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1