Reliability evaluation: a field experience from Motorola's cellular base transceiver systems

R. Bothwell, R. Donthamsetty, Z. Kania, R. Wesoloski
{"title":"Reliability evaluation: a field experience from Motorola's cellular base transceiver systems","authors":"R. Bothwell, R. Donthamsetty, Z. Kania, R. Wesoloski","doi":"10.1109/RAMS.1996.500685","DOIUrl":null,"url":null,"abstract":"The initial predicted MTBF with four hours MTTR, for a base transceiver system (BTS) is 4.0/5.65 years (MIL217/Bellcore standards). With the first 12 months of commercial operation, with actual field data, the MTBF is calculated to be 8.26 years (Bellcore), which is almost double the initial predicted reliability level. The improved manufacturing techniques with (six sigma quality), advanced system test methods, removal of all defective units in early stages of deployment resulted in tremendous reliability growth which exceeded the initial expected reliability. The downtime per year has decreased from 42 min/yr. to 29 min/yr. and the BTS availability has increased from 99.993% to 99.995%, or 5.39 sigma. Further refinement in the reliability is possible by introducing the following steps: (1) establish a minimum qualifying MTBF level for each component of each board; (2) validate the MTBF calculation methodology of vendor of each component; (3) improve MTBF of all weak FRUs by introducing redundancy schemes within each board; (4) introduce individual execution paths for each sector within a BTS; (5) continuous quality improvement techniques to eliminate escaping defects; (6) and establish BTS (HW and SW) stability level with an established release criteria.","PeriodicalId":393833,"journal":{"name":"Proceedings of 1996 Annual Reliability and Maintainability Symposium","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1996-01-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1996 Annual Reliability and Maintainability Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RAMS.1996.500685","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

The initial predicted MTBF with four hours MTTR, for a base transceiver system (BTS) is 4.0/5.65 years (MIL217/Bellcore standards). With the first 12 months of commercial operation, with actual field data, the MTBF is calculated to be 8.26 years (Bellcore), which is almost double the initial predicted reliability level. The improved manufacturing techniques with (six sigma quality), advanced system test methods, removal of all defective units in early stages of deployment resulted in tremendous reliability growth which exceeded the initial expected reliability. The downtime per year has decreased from 42 min/yr. to 29 min/yr. and the BTS availability has increased from 99.993% to 99.995%, or 5.39 sigma. Further refinement in the reliability is possible by introducing the following steps: (1) establish a minimum qualifying MTBF level for each component of each board; (2) validate the MTBF calculation methodology of vendor of each component; (3) improve MTBF of all weak FRUs by introducing redundancy schemes within each board; (4) introduce individual execution paths for each sector within a BTS; (5) continuous quality improvement techniques to eliminate escaping defects; (6) and establish BTS (HW and SW) stability level with an established release criteria.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
可靠性评估:摩托罗拉蜂窝基站收发器系统的现场经验
基本收发器系统(BTS)的初始预测MTBF(4小时MTTR)为4.0/5.65年(MIL217/Bellcore标准)。在商业运营的前12个月,根据实际的现场数据,计算出的MTBF为8.26年(Bellcore),几乎是最初预测可靠性水平的两倍。改进的制造技术(六西格玛质量),先进的系统测试方法,在部署的早期阶段消除所有有缺陷的单元,导致了可靠性的巨大增长,超出了最初的预期可靠性。每年的停机时间从42分钟/年减少。到29分钟/年。BTS的可用性从99.993%提高到99.995%,即5.39 sigma。通过引入以下步骤,可以进一步改进可靠性:(1)为每块板的每个组件建立最低合格MTBF水平;(2)验证各部件供应商的MTBF计算方法;(3)在各板内引入冗余方案,提高各弱fru的MTBF;(4)在BTS内为每个扇区引入单独的执行路径;(5)持续质量改进技术,以消除逃逸缺陷;(6)建立BTS (HW和SW)的稳定性水平,并制定发布标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of a fault isolation procedure [space station reliability] The reliability of error correcting code implementations [IC reliability assessment] Commercial-off-the shelf (COTS): a challenge to military equipment reliability A combined analysis approach to assessing requirements for safety critical real-time control systems Fault tree analysis and binary decision diagrams
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1