Improved Expression for Estimation of Leakage Inductance in E Core Transformer Using Energy Method

S. R. Thondapu, M. Borage, Y. D. Wanmode, P. Shrivastava
{"title":"Improved Expression for Estimation of Leakage Inductance in E Core Transformer Using Energy Method","authors":"S. R. Thondapu, M. Borage, Y. D. Wanmode, P. Shrivastava","doi":"10.1155/2012/635715","DOIUrl":null,"url":null,"abstract":"This paper proposes a simpler and more accurate expression for estimation of leakage inductance in E core transformer, which is the most widely used transformer structure. The derived expression for leakage inductance accounts for the flux extending into air. The finite element method (FEM) analysis is made on the secondary shorted transformer to observe the H-field pattern. The results obtained from FEM analysis are used for approximating the field that is extending into air to derive an expression for leakage inductance. This expression is experimentally validated on prototype transformers of different core dimensions.","PeriodicalId":412593,"journal":{"name":"Advances in Power Electronic","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Power Electronic","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2012/635715","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

This paper proposes a simpler and more accurate expression for estimation of leakage inductance in E core transformer, which is the most widely used transformer structure. The derived expression for leakage inductance accounts for the flux extending into air. The finite element method (FEM) analysis is made on the secondary shorted transformer to observe the H-field pattern. The results obtained from FEM analysis are used for approximating the field that is extending into air to derive an expression for leakage inductance. This expression is experimentally validated on prototype transformers of different core dimensions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用能量法估计E铁心变压器漏感的改进表达式
E铁心变压器是一种应用最广泛的变压器结构,本文提出了一种更简单、更准确的漏感估计表达式。导出的漏感表达式考虑了磁通延伸到空气中的情况。对二次短路变压器进行了有限元分析,观察了h场分布规律。利用有限元分析的结果,对延伸到空气中的电场进行近似,推导出泄漏电感的表达式。该表达式在不同铁芯尺寸的样机上进行了实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fault Handling Methods and Comparison for Different DC Breaker Topologies and MMC Topologies of the HVDC System A Novel Analog Circuit Design for Maximum Power Point Tracking of Photovoltaic Panels Quantitative Analysis of Efficiency Improvement of a Propulsion Drive by Using SiC Devices: A Case of Study Experimental Verification of a Battery Energy Storage System for Integration with Photovoltaic Generators Sensorless Control of Nonsinusoidal Permanent Magnet Brushless Motor Using Selective Torque Harmonic Elimination Control Method Based on Full-Order Sliding Mode Observer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1