M. Kennedy, D. Ristau, G. Dumitru, D. Sporea, Clementina A. Timus
{"title":"Calibration procedures for a 10.6-μm laser calorimeter","authors":"M. Kennedy, D. Ristau, G. Dumitru, D. Sporea, Clementina A. Timus","doi":"10.1117/12.312718","DOIUrl":null,"url":null,"abstract":"The paper presents the theoretical background of laser calorimetry as a method to investigate the absorptance of optical components, according to the recently adopted ISO Standard 11 551. An experimental set-up for optical absorption measurements, including a cw CO2 laser and a calorimetric chamber, is presented. The calibration of the laser calorimetric set-up is also described. The calibration involved several steps: laser power calibration, evaluation of chamber sensitivity, electrical calibration using electrically heated samples and optical calibration utilizing 100% absorptance samples. There were measured the conversion factors for the laser power and for the sample temperature; there were calculated over-all correction factors for the different substrates and they could be placed within +/- 4% around their mean value.","PeriodicalId":383583,"journal":{"name":"ROMOPTO International Conference on Micro- to Nano- Photonics III","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ROMOPTO International Conference on Micro- to Nano- Photonics III","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.312718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The paper presents the theoretical background of laser calorimetry as a method to investigate the absorptance of optical components, according to the recently adopted ISO Standard 11 551. An experimental set-up for optical absorption measurements, including a cw CO2 laser and a calorimetric chamber, is presented. The calibration of the laser calorimetric set-up is also described. The calibration involved several steps: laser power calibration, evaluation of chamber sensitivity, electrical calibration using electrically heated samples and optical calibration utilizing 100% absorptance samples. There were measured the conversion factors for the laser power and for the sample temperature; there were calculated over-all correction factors for the different substrates and they could be placed within +/- 4% around their mean value.