Precision calibration of patient care equipment as failure predictor.

Biotelemetry Pub Date : 1977-01-01
W H Buchsbaum
{"title":"Precision calibration of patient care equipment as failure predictor.","authors":"W H Buchsbaum","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Reliability of patient care equipment could be enhanced if failures could be predicted and repairs made on a routine instead of emergency basis. The paper describes the efforts of the Biomedical Engineering Department at Brookdale Hospital Medical Center to use changes in accuracy of selected parameters as failure predictor. Monthly precision tests of ECG rate computers, strip chart recorders and waveform analysis of defibrillator discharges were used in this experiment. For defibrillators and strip chart records failures could clearly be predicted but the results for ECG rate computers are still inconclusive.</p>","PeriodicalId":75602,"journal":{"name":"Biotelemetry","volume":"4 1","pages":"18-27"},"PeriodicalIF":0.0000,"publicationDate":"1977-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Reliability of patient care equipment could be enhanced if failures could be predicted and repairs made on a routine instead of emergency basis. The paper describes the efforts of the Biomedical Engineering Department at Brookdale Hospital Medical Center to use changes in accuracy of selected parameters as failure predictor. Monthly precision tests of ECG rate computers, strip chart recorders and waveform analysis of defibrillator discharges were used in this experiment. For defibrillators and strip chart records failures could clearly be predicted but the results for ECG rate computers are still inconclusive.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
作为故障预测器的病人护理设备的精确校准。
如果能够预测故障并在日常而不是紧急情况下进行维修,则可以提高病人护理设备的可靠性。本文描述了布鲁克代尔医院医学中心生物医学工程系使用选定参数的准确性变化作为失败预测器的努力。本实验采用心电率计算机月度精度测试、条形图记录仪和除颤器放电波形分析。对于除颤器和条形图记录,故障可以清楚地预测,但心电图率计算机的结果仍然不确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fourth international symposium on biotelemetry. Garmisch-Partenkirchen, FRG, May 28-June 2, 1978. Fundamental aspects of antimony thin film electrodes for pH measurement. Implantable telemetry system for long-term EMG. Telemetric motor activity in children. A preliminary study. Precision calibration of patient care equipment as failure predictor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1