Ambulatory monitoring of the electrocardiogram: an important aspect of pacemaker surveillance.

Biotelemetry Pub Date : 1977-01-01
D E Ward, A J Camm, R A Spurrell
{"title":"Ambulatory monitoring of the electrocardiogram: an important aspect of pacemaker surveillance.","authors":"D E Ward,&nbsp;A J Camm,&nbsp;R A Spurrell","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Of the 353 patients followed in the pacemaker surveillance clinic between July 1976 and July 1977, 25 patients complained of episodes of dizziness and faintness. 20 of these had normal pacing function and pacemaker parameters at routine clinic testing. 18 patients had 'demand' units and 2 had fixed-rate pacemakers. The indication for permanent pacing was complete heart block in 16 patients and sinoatrial disease in 5 patients. At clinic follow-up, there was unequivocal evidence of vertebrobasilar insufficiency in 5 patients and postural hypotension in 4 patients. In 11 patients, the cause of presyncope was not evident at the clinic. All patients were monitored by 24-hour tape recording until an episode of pre-syncope occurred. In 8 patients, there was evidence of intermittent failure to pace associated with the episodes of presyncope. In 2 patients, an additional cause for presyncope was found at clinic examination. Ambulatory 24-hour tape monitoring of the electrocardiogram is an important adjunct to pacemaker follow-up especially when other methods such as transtelephone monitoring are not available in the United Kingdom. Routine electronic testing of pacemaker function does not always reveal intermittent abnormalities related to changes in threshold or unstable electrode positions.</p>","PeriodicalId":75602,"journal":{"name":"Biotelemetry","volume":"4 3","pages":"109-14"},"PeriodicalIF":0.0000,"publicationDate":"1977-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Of the 353 patients followed in the pacemaker surveillance clinic between July 1976 and July 1977, 25 patients complained of episodes of dizziness and faintness. 20 of these had normal pacing function and pacemaker parameters at routine clinic testing. 18 patients had 'demand' units and 2 had fixed-rate pacemakers. The indication for permanent pacing was complete heart block in 16 patients and sinoatrial disease in 5 patients. At clinic follow-up, there was unequivocal evidence of vertebrobasilar insufficiency in 5 patients and postural hypotension in 4 patients. In 11 patients, the cause of presyncope was not evident at the clinic. All patients were monitored by 24-hour tape recording until an episode of pre-syncope occurred. In 8 patients, there was evidence of intermittent failure to pace associated with the episodes of presyncope. In 2 patients, an additional cause for presyncope was found at clinic examination. Ambulatory 24-hour tape monitoring of the electrocardiogram is an important adjunct to pacemaker follow-up especially when other methods such as transtelephone monitoring are not available in the United Kingdom. Routine electronic testing of pacemaker function does not always reveal intermittent abnormalities related to changes in threshold or unstable electrode positions.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
动态心电图监测:起搏器监测的一个重要方面。
在1976年7月至1977年7月间在起搏器监测诊所随访的353名患者中,有25名患者抱怨眩晕和昏厥发作。其中20例在常规临床测试中起搏功能和起搏器参数正常。18名患者有“需求”装置,2名患者有固定速率起搏器。永久性起搏的适应症为完全心脏传导阻滞16例,窦房疾病5例。在临床随访中,有明确证据表明5例患者出现椎基底动脉功能不全,4例患者出现体位性低血压。在11例患者中,晕厥前的病因在临床上并不明显。所有患者均接受24小时磁带监测,直至发生晕厥前发作。在8例患者中,有证据表明间歇性心律失常与晕厥前发作有关。在2例患者中,在临床检查中发现了晕厥前的其他原因。24小时动态心电图监护是心脏起搏器随访的重要辅助手段,特别是当英国没有其他方法如电话监护时。起搏器功能的常规电子测试并不总是显示与阈值变化或电极位置不稳定有关的间歇性异常。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fourth international symposium on biotelemetry. Garmisch-Partenkirchen, FRG, May 28-June 2, 1978. Fundamental aspects of antimony thin film electrodes for pH measurement. Implantable telemetry system for long-term EMG. Telemetric motor activity in children. A preliminary study. Precision calibration of patient care equipment as failure predictor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1