TINJAUAN PERENCANAAN GELAGAR BETON PRATEGANG PADA JEMBATAN BAKONGAN KECAMATAN PERMATA KABUPATEN BENAR MERIAH

Ghali Hari
{"title":"TINJAUAN PERENCANAAN GELAGAR BETON PRATEGANG PADA JEMBATAN BAKONGAN KECAMATAN PERMATA KABUPATEN BENAR MERIAH","authors":"Ghali Hari","doi":"10.30811/portal.v8i2.609","DOIUrl":null,"url":null,"abstract":"Bakongan bridge located in Bakongan village, Permata Subdistrict, Bener Meriah District. Based on the characteristics of the river, the bridge isplanned to Bakongan spans 13,6 meters long and 6 meters width. Girder longitudinal direction planned for the bridge is prestressed concrete girder type of post­ tension with the imposition of standard rules RSNI T-02-2005, RSNI T-12-2004 and Construction Manual 021/BM/201 J . Jn the early stages of planning done preliminary design to determine the dimensions of the main bridge, the calculation of the secondary structure are used as load analysis that occurs, the control voltage that occurs in the structure, post-tensile prestressing loss, sectional capacity, control deflection, and depiction. Quality of concrete used was Jc = 45 MPa, tendon used is seven strand wire with a diameter of  9,3 mm  inch diameter 51 mm shells tendon. Voltage tendonfpu = 1860 MPa, quality threaded steel reinforcement isfY = 320 MPa, and quality plain steel reinforcement isfY = 240 MPa. Moments that occur in the calculation  of girder 1502,0967 KNM combination III. Number of tendons obtained from the calculation is 5 to 35 pieces offruit on each strand tendons. Total loss of prestressing force obtained at 817,54 MPa or 34 %. Principal reinforcement used  Æ13 mm, Æ10-shear reinforcement used in the staging area 100 mm and g 10-600 mm in thefield area. Ultimate moment capacity of prestressed beams 3629664KN/m combination Ill of calculation. Greatest deflection is 0.0151 meters caused by a combination JV. Keywords: Concrete prestressed,  Post-tension girder, tendons, reinforcement","PeriodicalId":378653,"journal":{"name":"Portal: Jurnal Teknik Sipil","volume":"13 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Portal: Jurnal Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30811/portal.v8i2.609","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Bakongan bridge located in Bakongan village, Permata Subdistrict, Bener Meriah District. Based on the characteristics of the river, the bridge isplanned to Bakongan spans 13,6 meters long and 6 meters width. Girder longitudinal direction planned for the bridge is prestressed concrete girder type of post­ tension with the imposition of standard rules RSNI T-02-2005, RSNI T-12-2004 and Construction Manual 021/BM/201 J . Jn the early stages of planning done preliminary design to determine the dimensions of the main bridge, the calculation of the secondary structure are used as load analysis that occurs, the control voltage that occurs in the structure, post-tensile prestressing loss, sectional capacity, control deflection, and depiction. Quality of concrete used was Jc = 45 MPa, tendon used is seven strand wire with a diameter of  9,3 mm  inch diameter 51 mm shells tendon. Voltage tendonfpu = 1860 MPa, quality threaded steel reinforcement isfY = 320 MPa, and quality plain steel reinforcement isfY = 240 MPa. Moments that occur in the calculation  of girder 1502,0967 KNM combination III. Number of tendons obtained from the calculation is 5 to 35 pieces offruit on each strand tendons. Total loss of prestressing force obtained at 817,54 MPa or 34 %. Principal reinforcement used  Æ13 mm, Æ10-shear reinforcement used in the staging area 100 mm and g 10-600 mm in thefield area. Ultimate moment capacity of prestressed beams 3629664KN/m combination Ill of calculation. Greatest deflection is 0.0151 meters caused by a combination JV. Keywords: Concrete prestressed,  Post-tension girder, tendons, reinforcement
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bakongan桥位于Bener Meriah区Permata街道Bakongan村。根据这条河的特点,计划在巴孔安建造一座长13.6米、宽6米的大桥。主梁纵向规划为后张预应力混凝土主梁型,执行标准规则RSNI T-02-2005、RSNI T-12-2004和施工手册021/BM/ 201j。在规划前期做了初步设计,确定了主桥的尺寸,二次结构的计算是用来进行荷载分析的,结构中发生的控制电压,张后预应力损失,截面承载力,控制挠度,以及描绘。采用的混凝土质量为Jc = 45 MPa,筋采用的是直径为9.3 mm英寸直径为51 mm的七股钢丝壳筋。电压tendonfpu = 1860 MPa,优质螺纹钢筋isfY = 320 MPa,优质素钢钢筋isfY = 240 MPa。KNM组合III型梁1502、0967计算中出现的弯矩。计算得到的筋数为每根筋上有5 ~ 35根水果。预应力总损失在817,54 MPa或34%。主钢筋使用Æ13 mm, Æ10-shear钢筋使用在集结地100 mm, g - 10-600 mm在野战区。预应力梁的极限弯矩承载力为3629664KN/m组合梁。组合JV产生的最大挠度为0.0151米。关键词:预应力混凝土,后张梁,筋,配筋
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prototype Jembatan Tipe Plate Girder U (PGU) dengan Lantai Orthotropic Komposit Evaluasi Deskriptif Sistem Pembayaran Bus Rapid Transit Estimasi Biaya Proyek pada Kontrakor Skala Kecil di Bali pada Masa Pandemi COVID-19 3 Floor Luxury House Structure Design Planning Using ETABS Software Cover
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1