Instrumented timed up and go: Fall risk assessment based on inertial wearable sensors

Joana Silva, I. Sousa
{"title":"Instrumented timed up and go: Fall risk assessment based on inertial wearable sensors","authors":"Joana Silva, I. Sousa","doi":"10.1109/MeMeA.2016.7533778","DOIUrl":null,"url":null,"abstract":"Strategies for fall risk assessment are currently not multifactorial neither implemented as a regular assessment of health status in clinics or hospital. The reason could be related with a lack of an easy to implement, complete and objective test to assess elderly's fall risk level. More recently, inertial wearable sensors have been used in combination with standard tests to evaluate the performance of the person during each phase of the test in an objective way. This paper proposes a methodology for collecting and analyzing the Timed-Up and Go (TUG) test instrumented with wearable inertial sensors. An automatic algorithm to segment the TUG test into three components was implemented prior to feature extraction. Overall, features from the walking and first turning phases of the tests could provide meaningful information to differentiate groups of high and low fall risk.","PeriodicalId":221120,"journal":{"name":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"8 18","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2016.7533778","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

Strategies for fall risk assessment are currently not multifactorial neither implemented as a regular assessment of health status in clinics or hospital. The reason could be related with a lack of an easy to implement, complete and objective test to assess elderly's fall risk level. More recently, inertial wearable sensors have been used in combination with standard tests to evaluate the performance of the person during each phase of the test in an objective way. This paper proposes a methodology for collecting and analyzing the Timed-Up and Go (TUG) test instrumented with wearable inertial sensors. An automatic algorithm to segment the TUG test into three components was implemented prior to feature extraction. Overall, features from the walking and first turning phases of the tests could provide meaningful information to differentiate groups of high and low fall risk.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
仪器计时up and go:基于惯性可穿戴传感器的跌倒风险评估
跌倒风险评估战略目前不是多因素的,也不是作为诊所或医院健康状况的定期评估来实施的。其原因可能与缺乏一种易于实施、完整和客观的测试来评估老年人跌倒风险水平有关。最近,惯性可穿戴传感器已与标准测试结合使用,以客观的方式评估人在测试每个阶段的表现。提出了一种基于可穿戴惯性传感器采集和分析拖运(TUG)测试结果的方法。在特征提取之前,实现了一种自动将TUG测试分为三个部分的算法。总的来说,测试的行走和第一次转弯阶段的特征可以提供有意义的信息来区分高和低跌倒风险组。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of temperature rise in tissue — Mimicking material induced by a HIFU transducer Influence of fiber Bragg grating length on temperature measurements in laser-irradiated organs Optimal peripheral measurement point for the assessment of preterm patients in intensive care units Classification of cognitive and resting states of the brain using EEG features Scoring systems in dermatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1