A new numeric busbar protection scheme using Bayes point machine

Soumitri Jena, B. Bhalja
{"title":"A new numeric busbar protection scheme using Bayes point machine","authors":"Soumitri Jena, B. Bhalja","doi":"10.1109/APPEEC.2017.8309013","DOIUrl":null,"url":null,"abstract":"Schemes adopted for protection of busbar face major challenges in terms of speed, sensitivity, and immunity against current transformer (CT) saturation. This paper reports a new busbar protection scheme using Bayes Point Machine (BPM). A substation model with double bus configuration has been simulated in PSCAD and one cycle post-fault current samples are utilized to identify the fault zone. The proposed algorithm has been tested for diversified fault scenarios including the cases for which the conventional line differential protection scheme (87L) is likely to maloperate. BPM is found to be more than 99% accurate while identifying the correct fault zone. A comparative evaluation suggests the superiority of BPM among other machine learning based classifiers.","PeriodicalId":247669,"journal":{"name":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"143 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2017.8309013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Schemes adopted for protection of busbar face major challenges in terms of speed, sensitivity, and immunity against current transformer (CT) saturation. This paper reports a new busbar protection scheme using Bayes Point Machine (BPM). A substation model with double bus configuration has been simulated in PSCAD and one cycle post-fault current samples are utilized to identify the fault zone. The proposed algorithm has been tested for diversified fault scenarios including the cases for which the conventional line differential protection scheme (87L) is likely to maloperate. BPM is found to be more than 99% accurate while identifying the correct fault zone. A comparative evaluation suggests the superiority of BPM among other machine learning based classifiers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新的基于贝叶斯点机的数字母线保护方案
采用的母线保护方案在速度、灵敏度和抗电流互感器(CT)饱和方面面临重大挑战。本文提出了一种新的基于贝叶斯点机的母线保护方案。在PSCAD中对双母线配置的变电站模型进行了仿真,并利用故障后一个周期的电流样本来识别故障区域。该算法已在多种故障情况下进行了测试,包括传统线路差动保护方案(87L)可能发生故障的情况。在识别正确的故障区域时,BPM的准确率超过99%。对比评估表明BPM在其他基于机器学习的分类器中具有优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel modulation strategy for active rectification of a snubber less soft-switched single stage 30 high frequency link DC-AC converter Implementation of social spider optimization for optimized hydel-thermic operational delineation Frequency Response Analysis (FRA) in power transformers: An approach to locate inter-disk SC fault Fault estimation with analytical cable model for MMC-HVDC in offshore applications Modified current control technique for grid synchronization in voltage source converters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1