C. Contreras-Martinez, B. Giaccone, I. Gonin, T. Khabiboulline, O. Melnychuk, Y. Pischalnikov, S. Posen, O. Pronitchev, J. Yun
{"title":"Testing of the 2.6 GHz SRF Cavity Tuner For The Dark Photon Experiment at 2 K","authors":"C. Contreras-Martinez, B. Giaccone, I. Gonin, T. Khabiboulline, O. Melnychuk, Y. Pischalnikov, S. Posen, O. Pronitchev, J. Yun","doi":"10.2172/1988464","DOIUrl":null,"url":null,"abstract":"At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.","PeriodicalId":179099,"journal":{"name":"Testing of the 2.6 GHz SRF Cavity Tuner For The Dark Photon Experiment at 2 K","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Testing of the 2.6 GHz SRF Cavity Tuner For The Dark Photon Experiment at 2 K","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2172/1988464","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.