Characteristic analysis of HVDC system with shunt capacitance commutated converter

C. Zhai, Zhiwen Zhang, L. Luo, Xin Sun, Shubo Sun
{"title":"Characteristic analysis of HVDC system with shunt capacitance commutated converter","authors":"C. Zhai, Zhiwen Zhang, L. Luo, Xin Sun, Shubo Sun","doi":"10.1109/APPEEC.2017.8308902","DOIUrl":null,"url":null,"abstract":"In this paper, a novel HVDC system is proposed for using Shunt Capacitance Commutated Converter (SCCC), and analysis of work and wiring method are given. The basic idea of the SCCC is connect the capacitors in parallel between the converter transformers and the converters at the valve winding. The parallel capacitor is used to compensate for the vast majority of the inductive reactive power which can be required during the operation time. It is proved that the SCCC not only has the advantages of reducing the failure chance in commutation of the inverter, but also can makes the capacity of the converter transformer be utilized fully. The 500 kV HVDC monopole operation system about Huizhou City, Guangdong Province Echeng as an example, conducted by simulation of the system software (MATLAB). Gotting the AC side voltage and current waveforms and the DC side voltage and current waveforms during the operation of the SCCC. It is shown that the SCCC can not only overcomes the inherent defects of the traditional HVDC converter, but also can optimizes the operation state of the converter transformer and the whole systems.","PeriodicalId":247669,"journal":{"name":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"136 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2017.8308902","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, a novel HVDC system is proposed for using Shunt Capacitance Commutated Converter (SCCC), and analysis of work and wiring method are given. The basic idea of the SCCC is connect the capacitors in parallel between the converter transformers and the converters at the valve winding. The parallel capacitor is used to compensate for the vast majority of the inductive reactive power which can be required during the operation time. It is proved that the SCCC not only has the advantages of reducing the failure chance in commutation of the inverter, but also can makes the capacity of the converter transformer be utilized fully. The 500 kV HVDC monopole operation system about Huizhou City, Guangdong Province Echeng as an example, conducted by simulation of the system software (MATLAB). Gotting the AC side voltage and current waveforms and the DC side voltage and current waveforms during the operation of the SCCC. It is shown that the SCCC can not only overcomes the inherent defects of the traditional HVDC converter, but also can optimizes the operation state of the converter transformer and the whole systems.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
并联电容整流变换器高压直流系统特性分析
本文提出了一种采用并联电容整流变换器(SCCC)的新型高压直流系统,并对其工作原理和接线方法进行了分析。SCCC的基本思想是在阀绕组的换流变压器和换流器之间并联电容器。并联电容器用于补偿在运行期间所需的绝大部分感应无功功率。实验证明,SCCC不仅具有降低逆变器换相故障几率的优点,而且可以使换流变压器的容量得到充分利用。以广东省惠州市鄂城500kv高压直流单极子运行系统为例,通过系统软件(MATLAB)进行仿真。得到SCCC工作时的交流侧电压、电流波形和直流侧电压、电流波形。研究表明,SCCC不仅可以克服传统高压直流变换器固有的缺陷,而且可以优化变换器和整个系统的运行状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel modulation strategy for active rectification of a snubber less soft-switched single stage 30 high frequency link DC-AC converter Implementation of social spider optimization for optimized hydel-thermic operational delineation Frequency Response Analysis (FRA) in power transformers: An approach to locate inter-disk SC fault Fault estimation with analytical cable model for MMC-HVDC in offshore applications Modified current control technique for grid synchronization in voltage source converters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1