Peculiarities of the Reconstruction of the Relay Protection of a Transformer Substation

N. Filimonenko, Kostiantyn Filimonenko, Hryhoriy Melkonov
{"title":"Peculiarities of the Reconstruction of the Relay Protection of a Transformer Substation","authors":"N. Filimonenko, Kostiantyn Filimonenko, Hryhoriy Melkonov","doi":"10.1109/ESS57819.2022.9969294","DOIUrl":null,"url":null,"abstract":"The paper presents the results of the analysis for the implementation of the transition of the existing 6 kV Substation to voltage class 35 kV with reconfiguration and automation of electrical equipment of the substation - this is a necessary and priority step to improve the efficiency of electrical networks. When considering in detail all the advantages of the presented terminals the most acceptable is the Sepam (Schneider Electric) type relay protection. To achieve safe and reliable operation of the power supply system, the substation must be equipped with microprocessor relay protection devices. In addition to the necessary functioning of the terminals can be equipped with interface parts of the lower stage, which are needed when building an automated design (configuration) of power facilities. The aim of the paper is to study the possibility and implementation of equipping microprocessor-based relay protection of the substation to ensure the normal safe and reliable operation of the substation power supply system. Switch to relay protection and electrical automation device on microprocessor-based element base.","PeriodicalId":432063,"journal":{"name":"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 8th International Conference on Energy Smart Systems (ESS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESS57819.2022.9969294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The paper presents the results of the analysis for the implementation of the transition of the existing 6 kV Substation to voltage class 35 kV with reconfiguration and automation of electrical equipment of the substation - this is a necessary and priority step to improve the efficiency of electrical networks. When considering in detail all the advantages of the presented terminals the most acceptable is the Sepam (Schneider Electric) type relay protection. To achieve safe and reliable operation of the power supply system, the substation must be equipped with microprocessor relay protection devices. In addition to the necessary functioning of the terminals can be equipped with interface parts of the lower stage, which are needed when building an automated design (configuration) of power facilities. The aim of the paper is to study the possibility and implementation of equipping microprocessor-based relay protection of the substation to ensure the normal safe and reliable operation of the substation power supply system. Switch to relay protection and electrical automation device on microprocessor-based element base.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
变电站继电保护改造的特点
本文介绍了通过变电站电气设备的改造和自动化,实现现有6千伏变电站向35千伏电压等级过渡的分析结果,这是提高电网效率的必要和优先步骤。当详细考虑所有端子的优点时,最可接受的是Sepam(施耐德电气)型继电保护。为了实现供电系统的安全可靠运行,变电站必须配备微处理器继电保护装置。除了终端的必要功能外,还可以配备下层的接口部件,这是建立自动化设计(配置)电力设施时所需要的。本文的目的是研究在变电站安装基于微处理器的继电保护,以保证变电站供电系统正常安全可靠运行的可能性和实现。开关到继电保护和电气自动化装置在微处理器为基础的元件基础上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Monitoring of loss power components in three-phase low-voltage power supply systems A Fault Tolerant Multilevel Converter Topology for an 8/6 SRM Drive Based on a Cross-Switched Configuration Adjustment of Two Circuits System of Active Shielding of the Magnetic Field Generated by Overhead Power Lines Analysis of the Probable Decrease of Load Shedding Reserve in Power System of Ukraine at Installed Capacity of Renewable Energy Sources Possibilities of Electricity Generation Using Small Wind Generators in Eastern Ukraine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1