Technical challenges using magneto-inertial sensors for gait analysis

L. Gastaldi, V. Rosso, V. Gabola, V. Agostini, M. M. L. Frutos, M. Knaflitz, Ryo Takeda, S. Tadano
{"title":"Technical challenges using magneto-inertial sensors for gait analysis","authors":"L. Gastaldi, V. Rosso, V. Gabola, V. Agostini, M. M. L. Frutos, M. Knaflitz, Ryo Takeda, S. Tadano","doi":"10.1109/MeMeA.2016.7533746","DOIUrl":null,"url":null,"abstract":"Magneto-Inertial Measurement Units (MIMUs) are gathering an increasing consensus in human motion analysis. However, applications such as clinical gait analysis require reliable, repeatable and accurate measurements of gait parameters up to a level that it is not easily achievable with MIMUs. We pointed out some specific technical challenges that we encountered in the use of the MIMUs-based H-gait system, pertaining to 1) calibration procedure and 2) high dispersion of ankle joint kinematic curves. We described how we solved these issues: 1) shifting from a manual to a semi-automatic calibration procedure and 2) obtaining an optimal MIMUs positioning on the foot. Joint kinematic results were validated against those acquired with a standard electromechanical system (STEP32).","PeriodicalId":221120,"journal":{"name":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2016.7533746","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Magneto-Inertial Measurement Units (MIMUs) are gathering an increasing consensus in human motion analysis. However, applications such as clinical gait analysis require reliable, repeatable and accurate measurements of gait parameters up to a level that it is not easily achievable with MIMUs. We pointed out some specific technical challenges that we encountered in the use of the MIMUs-based H-gait system, pertaining to 1) calibration procedure and 2) high dispersion of ankle joint kinematic curves. We described how we solved these issues: 1) shifting from a manual to a semi-automatic calibration procedure and 2) obtaining an optimal MIMUs positioning on the foot. Joint kinematic results were validated against those acquired with a standard electromechanical system (STEP32).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用磁惯性传感器进行步态分析的技术挑战
磁惯性测量单元(mimu)在人体运动分析中获得越来越多的共识。然而,临床步态分析等应用需要可靠,可重复和准确的步态参数测量,达到mimu不容易实现的水平。我们指出了在使用基于mimi的h -步态系统时遇到的一些具体的技术挑战,涉及到1)校准程序和2)踝关节运动曲线的高度分散。我们描述了如何解决这些问题:1)从手动转向半自动校准程序;2)在脚上获得最佳的mimu定位。关节运动学结果与标准机电系统(STEP32)获得的结果进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Investigation of temperature rise in tissue — Mimicking material induced by a HIFU transducer Influence of fiber Bragg grating length on temperature measurements in laser-irradiated organs Optimal peripheral measurement point for the assessment of preterm patients in intensive care units Classification of cognitive and resting states of the brain using EEG features Scoring systems in dermatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1