Quantitative analysis of diffraction-limited three-dimensional single secretory vesicle tracking in live neuroendocrine cells

D.D. Li, T. Liang, A. Qu
{"title":"Quantitative analysis of diffraction-limited three-dimensional single secretory vesicle tracking in live neuroendocrine cells","authors":"D.D. Li, T. Liang, A. Qu","doi":"10.1109/ICNIC.2005.1499883","DOIUrl":null,"url":null,"abstract":"Neuroendocrine cells release hormones and transmitters by regulated exocytosis of secretory vesicles. Three-dimensional (3D) tracking of single secretory vesicles throughout live whole cells is crucial for understanding the intracellular trafficking of secretory vesicles. But one notable problem with 3D particle tracking is that the lateral and axial resolution is not equivalent for 3D live-cell images, which is attributed to the diffraction limit inherent to the microscope. How the performance of particle tracking is affected by diffraction-limited images is still unclear. Here we show, employing both centroid and Gaussian-fit tracking algorithm to monitor sub-pixel positions of single fluorescent particles, that the performance of three-dimensional single particle tracking is nonisotropic. The efficacy of the particle tracking in the axial direction is much lower than that in the lateral direction. Gaussian-fit tracking algorithm provides better performance in the axial direction at low signal-to-noise levels around or below 10. Using neuroendocrine cell line PC12, we illustrate the feasibility of Gaussian-fit algorithm to follow the mobility of single secretory vesicles in all three dimensions.","PeriodicalId":169717,"journal":{"name":"Proceedings. 2005 First International Conference on Neural Interface and Control, 2005.","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. 2005 First International Conference on Neural Interface and Control, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICNIC.2005.1499883","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Neuroendocrine cells release hormones and transmitters by regulated exocytosis of secretory vesicles. Three-dimensional (3D) tracking of single secretory vesicles throughout live whole cells is crucial for understanding the intracellular trafficking of secretory vesicles. But one notable problem with 3D particle tracking is that the lateral and axial resolution is not equivalent for 3D live-cell images, which is attributed to the diffraction limit inherent to the microscope. How the performance of particle tracking is affected by diffraction-limited images is still unclear. Here we show, employing both centroid and Gaussian-fit tracking algorithm to monitor sub-pixel positions of single fluorescent particles, that the performance of three-dimensional single particle tracking is nonisotropic. The efficacy of the particle tracking in the axial direction is much lower than that in the lateral direction. Gaussian-fit tracking algorithm provides better performance in the axial direction at low signal-to-noise levels around or below 10. Using neuroendocrine cell line PC12, we illustrate the feasibility of Gaussian-fit algorithm to follow the mobility of single secretory vesicles in all three dimensions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
活体神经内分泌细胞衍射受限三维单分泌囊泡跟踪的定量分析
神经内分泌细胞通过调节分泌囊泡的胞外分泌来释放激素和递质。在整个活细胞中对单个分泌囊泡进行三维(3D)跟踪对于理解分泌囊泡的细胞内运输至关重要。但是,三维粒子跟踪的一个值得注意的问题是,横向和轴向分辨率不等同于三维活细胞图像,这是由于显微镜固有的衍射极限。衍射受限图像对粒子跟踪性能的影响尚不清楚。本文采用质心和高斯拟合跟踪算法监测单个荧光粒子的亚像素位置,表明三维单粒子跟踪的性能是非各向同性的。颗粒在轴向的跟踪效果远低于横向的跟踪效果。高斯拟合跟踪算法在轴向低信噪比在10左右或以下时提供更好的性能。利用神经内分泌细胞系PC12,我们证明了高斯拟合算法在所有三个维度上跟踪单个分泌囊泡移动的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical applications of BION/sup TM/ microstimulators Development of ultra small two-channel system of EEG radio telemetry Experiment research on the method of monitoring the depth of anesthesia Controlling epileptic seizures EEG with a dynamic neural population model Wavelet transform analyzing and real-time learning method for myoelectric signal in motion discrimination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1