{"title":"Harmonic interference elimination by an active comb filter [ECG application]","authors":"Chang-Tar Tsai, Hsiao-Lung Chan, C. Tseng, Chien-Ping Wu","doi":"10.1109/IEMBS.1994.415235","DOIUrl":null,"url":null,"abstract":"A new approach for an active comb filter design is proposed to remove the difficult harmonic interference contaminating the biomedical signals. The filter consists of four narrow-band bandpass filters. The center frequency of each bandpass filters is just the unwanted frequency characterized by the harmonic interference. The circuit demonstrates the capability to eliminate the interference of 60, 180, 300, and 420 Hz. The general 741 type operational amplifier has been used to realize the circuit presented. Triangular wave testing shows the effectiveness of harmonic interference cancellation.<<ETX>>","PeriodicalId":344622,"journal":{"name":"Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1994.415235","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

A new approach for an active comb filter design is proposed to remove the difficult harmonic interference contaminating the biomedical signals. The filter consists of four narrow-band bandpass filters. The center frequency of each bandpass filters is just the unwanted frequency characterized by the harmonic interference. The circuit demonstrates the capability to eliminate the interference of 60, 180, 300, and 420 Hz. The general 741 type operational amplifier has been used to realize the circuit presented. Triangular wave testing shows the effectiveness of harmonic interference cancellation.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
有源梳状滤波器消除谐波干扰[心电应用]
针对生物医学信号中难以处理的谐波干扰,提出了一种新的有源梳状滤波器设计方法。该滤波器由四个窄带带通滤波器组成。每个带通滤波器的中心频率就是谐波干扰所表征的不需要的频率。该电路演示了消除60、180、300和420 Hz干扰的能力。该电路采用通用的741型运算放大器来实现。三角波测试表明了谐波干扰消除的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid from skin Early detection of infection and rejection in lung transplantation Temperature controlled electrosurgical vessel sealing Detection of glucose using Raman spectroscopy Fractal analysis for the adherent platelets under flow conditions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1