{"title":"Flashover influence of fog rate on the characteristics of polluted silicone-rubber insulators","authors":"A. Krzma, M. Albano, A. Haddad","doi":"10.1109/UPEC.2017.8231958","DOIUrl":null,"url":null,"abstract":"This paper presents an experimental investigation on flashover performance of silicone rubber (SiR) outdoor insulators. The AC flashover-voltage (FOV) of selected insulator designs is measured adopting the clean fog test and a high voltage ramp test. A conventional insulator design with a plain surface has been tested and compared with insulators having a textured surface. The FOV dependency on the pollution severity level is quantified. The influence of SiR profiles and wetting rate on the mean FOV are also investigated. For different ranges of wetting and pollution severity conditions, the results showed that the textured insulator designs exhibit an increased flashover performance compared with conventional non-textured insulators. Textured insulators can offer an increased FOV performance up to 16% compared with the average FOV of the conventional insulator. Under lower fog rate, the FOV level for both insulator types does not gradually increase with the testing time but is characterised by a U-trend. For moderate and high fog rates, a stable increase in FOV is observed. The result gives an indication that the average FOV is substantially affected by the higher fog rate for both insulator profiles. Furthermore, a greater improvement was gained on the mean FOV under textured design.","PeriodicalId":272049,"journal":{"name":"2017 52nd International Universities Power Engineering Conference (UPEC)","volume":"219 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 52nd International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2017.8231958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

This paper presents an experimental investigation on flashover performance of silicone rubber (SiR) outdoor insulators. The AC flashover-voltage (FOV) of selected insulator designs is measured adopting the clean fog test and a high voltage ramp test. A conventional insulator design with a plain surface has been tested and compared with insulators having a textured surface. The FOV dependency on the pollution severity level is quantified. The influence of SiR profiles and wetting rate on the mean FOV are also investigated. For different ranges of wetting and pollution severity conditions, the results showed that the textured insulator designs exhibit an increased flashover performance compared with conventional non-textured insulators. Textured insulators can offer an increased FOV performance up to 16% compared with the average FOV of the conventional insulator. Under lower fog rate, the FOV level for both insulator types does not gradually increase with the testing time but is characterised by a U-trend. For moderate and high fog rates, a stable increase in FOV is observed. The result gives an indication that the average FOV is substantially affected by the higher fog rate for both insulator profiles. Furthermore, a greater improvement was gained on the mean FOV under textured design.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
雾率对污染硅橡胶绝缘子特性的闪络影响
对硅橡胶(SiR)室外绝缘子的闪络性能进行了试验研究。采用洁净雾试验和高压斜坡试验测量了不同绝缘子设计的交流闪络电压。传统的绝缘子平面设计已被测试并与具有纹理表面的绝缘子进行了比较。对视场对污染严重程度的依赖性进行了量化。研究了SiR分布和润湿速率对平均视场的影响。在不同的润湿和污染严重程度条件下,结果表明,与传统的非纹理绝缘子相比,纹理绝缘子设计具有更高的闪络性能。与传统绝缘体的平均FOV相比,纹理绝缘体可以提供高达16%的FOV性能。在雾率较低的情况下,两种绝缘子的视场水平都不随测试时间的增加而逐渐增加,而是呈u型趋势。对于中等和高雾率,观察到视场的稳定增加。结果表明,高雾率对两种绝缘子的平均视场都有很大影响。此外,纹理化设计下的平均视场有较大的改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Power quality observations for solar photovoltaic inverters under part-load operation Distributed electricity markets and distribution locational marginal prices: A review Energy storage day-ahead scheduling to reduce grid energy export and increase self-consumption for micro-grid and small power park applications Potential solutions to the challenges of low inertia power systems with a case study concerning synchronous condensers Risk assessment due to electricity price forecast uncertainty in UK electricity market
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1