{"title":"Insulation status detection on the high voltage bushing by FRA method","authors":"Z. Chunyan, Gan Jinxing, Nie Dexin, Du Zhenbo, Tang Zhenpeng, Deng Xiao-qiang","doi":"10.1109/ISGT-ASIA.2012.6303214","DOIUrl":null,"url":null,"abstract":"This paper mainly discusses the mechanism for FRA method on bushing insulation detection. It builds several RC models of the bushing instruction in MATLAB, as well as does some simulation work to observe the change of the FRA curve with different parameters. It also takes the influence of the valve wire into consider and get some useful conclusions. Simulation results show that the obvious indentation in the FRA curve will appear when the bushing has some insulation defects. The sum and change state of the indentation in FRA curve is related to the degree and relaxation polarization of the insulation defects of the bushing. It is found that the simulation and on-spot detection curves have tallies with each other, which verifies the feasibility of FRA method in this field.","PeriodicalId":330758,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies","volume":"73 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-ASIA.2012.6303214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper mainly discusses the mechanism for FRA method on bushing insulation detection. It builds several RC models of the bushing instruction in MATLAB, as well as does some simulation work to observe the change of the FRA curve with different parameters. It also takes the influence of the valve wire into consider and get some useful conclusions. Simulation results show that the obvious indentation in the FRA curve will appear when the bushing has some insulation defects. The sum and change state of the indentation in FRA curve is related to the degree and relaxation polarization of the insulation defects of the bushing. It is found that the simulation and on-spot detection curves have tallies with each other, which verifies the feasibility of FRA method in this field.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用FRA法检测高压套管绝缘状态
本文主要讨论了FRA法在套管绝缘检测中的作用机理。在MATLAB中建立了套管指令的几个RC模型,并进行了仿真工作,观察了不同参数下FRA曲线的变化。同时考虑了阀丝的影响,得出了一些有益的结论。仿真结果表明,当套管存在一定的绝缘缺陷时,FRA曲线会出现明显的压痕。FRA曲线上压痕的总和和变化状态与套管绝缘缺陷的程度和弛豫极化有关。仿真结果与现场实测曲线吻合较好,验证了FRA方法在该领域的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wind-photovoltaic-storage system optimal control scheme based on generation scheduling Smart grid oriented smart substation characteristics analysis Studies on practical Small Signal Stability Region of electrical power systems A survey of communication technology in distribution network An interior point method based on continuous Newton's method for optimal power flow
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1