{"title":"Insulating Liquids, an Alternative to Silicone Gel for Power Electronic Devices","authors":"Ouassim Agri, J. Augé, E. Vagnon, F. Buret","doi":"10.1109/EIC43217.2019.9046577","DOIUrl":null,"url":null,"abstract":"This paper studies the breakdown voltage for different insulating materials encapsulating power electronic devices. A comparison between some liquids and silicone gel is carried out. The 50 Hz AC voltage tests were performed according to the IEC 60156 specifications. The same process was applied to the DC voltage tests due to a lack of standard procedure concerning DC voltage tests on liquids. In each case, a ceramic substrate was placed in a container filled with the insulating material. A voltage was applied between two electrodes glued on the substrate. Mineral, both synthetic and natural ester oils and silicone gel were tested. The voltages of breakdown between oils were quite similar in AC and DC. The gel is more resistant to DC stress even though its self-healing is less than the liquids investigated.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046577","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper studies the breakdown voltage for different insulating materials encapsulating power electronic devices. A comparison between some liquids and silicone gel is carried out. The 50 Hz AC voltage tests were performed according to the IEC 60156 specifications. The same process was applied to the DC voltage tests due to a lack of standard procedure concerning DC voltage tests on liquids. In each case, a ceramic substrate was placed in a container filled with the insulating material. A voltage was applied between two electrodes glued on the substrate. Mineral, both synthetic and natural ester oils and silicone gel were tested. The voltages of breakdown between oils were quite similar in AC and DC. The gel is more resistant to DC stress even though its self-healing is less than the liquids investigated.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
绝缘液体——电力电子器件中硅凝胶的替代品
本文研究了不同绝缘材料封装电力电子器件时的击穿电压。对一些液体和硅凝胶进行了比较。50hz交流电压试验按照IEC 60156规范进行。由于缺乏关于液体直流电压测试的标准程序,因此将相同的过程应用于直流电压测试。在每种情况下,将陶瓷衬底放置在充满绝缘材料的容器中。在粘在基板上的两个电极之间施加电压。矿物,合成和天然酯油和硅凝胶进行了测试。油之间的击穿电压在交流和直流中非常相似。尽管这种凝胶的自愈能力比所研究的液体要弱,但它对直流应力的抵抗力更强。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Diagnostic Testing of Power Cable Insulation For Reliable Smart Grid Operation Investigation of the Thickness Effect on DC Breakdown Strength for HVDC Flexible Cable Insulation Associated with Space Charge Classification of Insulating Liquids Thermal Treatment Using Infrared Spectroscopy and Multivariate Statistical Method Study on the Ageing Characteristics of Persea Americana Oil as an Alternative Transformer Insulation oil Evaluation of Nano-Composite XLPE Compound on Accelerated Aging Cable Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1