Electrolyzer Degradation influence on power electronics performance for 6-pulse thyristor rectifier in a large-scale water electrolyzer

M. Keddar, Marcos Da Conceicao, M. Doumbia, Zhifeng Zhang
{"title":"Electrolyzer Degradation influence on power electronics performance for 6-pulse thyristor rectifier in a large-scale water electrolyzer","authors":"M. Keddar, Marcos Da Conceicao, M. Doumbia, Zhifeng Zhang","doi":"10.1109/IREC56325.2022.10002014","DOIUrl":null,"url":null,"abstract":"Water electrolyzers require a high DC power input that can sustain the economic hydrogen production rate. During the conversion from AC to DC, power quality may be affected due to the nonlinearity of each component. In this work, we predict the influence of electrolyzer degradation on power electronics output over a long period of operation. Counterintuitively, rather than decreasing power quality, results show that the power quality increased with the electrolyzer degradation in a 6-pulse thyristorbased solution. Simulation results were partially validated with experimental data from an industrial 20 MW scale PEM electrolyzer.","PeriodicalId":115939,"journal":{"name":"2022 13th International Renewable Energy Congress (IREC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 13th International Renewable Energy Congress (IREC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IREC56325.2022.10002014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Water electrolyzers require a high DC power input that can sustain the economic hydrogen production rate. During the conversion from AC to DC, power quality may be affected due to the nonlinearity of each component. In this work, we predict the influence of electrolyzer degradation on power electronics output over a long period of operation. Counterintuitively, rather than decreasing power quality, results show that the power quality increased with the electrolyzer degradation in a 6-pulse thyristorbased solution. Simulation results were partially validated with experimental data from an industrial 20 MW scale PEM electrolyzer.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电解槽退化对大型水电解槽中6脉冲晶闸管整流器电力电子性能的影响
水电解槽需要高直流功率输入,以维持经济的制氢率。在交直流转换过程中,由于各部件的非线性,可能会影响电能质量。在这项工作中,我们预测了电解槽退化对长期运行的电力电子输出的影响。与直觉相反,结果表明,在6脉冲晶闸管溶液中,电能质量随着电解槽的退化而增加,而不是降低。仿真结果与20 MW工业规模PEM电解槽的实验数据进行了部分验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Supercritical Water Gasification of Tunisian Agricultural Waste for Energy Recovery: Comparative thermodynamic study of sustainable H2 rich syngas production using ASPEN PLUS Effect of solar radiation on the temperature of house walls facing the four cardinal points in the summer in Ouled Sidi Brahim (Algeria) Modelling and Estimation of The Optimum Tilt Angle of Photovoltaic Systems, Case Study: Libya A Case Study of Jordanian Power Grid Stability and Sustainability with and Without an External Grid Tie Line Mechanical Wind pumping system based on Hydropumped storage
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1