{"title":"Recommendations for Selection, Installation and Maintenance of Substation Transformers","authors":"D. Durocher, Marc C. Elliott, David C. Koehler, Emily Held","doi":"10.1109/PPIC47846.2021.9620454","DOIUrl":null,"url":null,"abstract":"For the past several years, there has been confusion surrounding both factory and field testing of liquid filled distribution substation transformers installed in industry. With the advent of new ester-based fluids, new standards have been developed that impact selection, installation and maintenance of liquid-filled transformers. This article will focus on established standards for both factory and field testing and recommended tests during scheduled rotational outages. Typical ratings for distribution substation transformers applied in process industries range from 112.5 kVA through 10,000 kVA three-phase, at 50 or 60 Hertz, with primary voltage at 34,500 volts and below and secondary voltage at 4,160 volts and below. Not included in the scope of this paper are dry-type distribution transformers, pad-mounted distribution transformers or power transformers with ratings up to 100,000 kVA and 230 kVA. Field testing recommendations focus on dissolved gas analysis (DGA) testing and understanding/trending test results will be covered. A case study outlining recent testing, results and lessons learned for an integrated paper mill in the U.S. Pacific Northwest will be reviewed.","PeriodicalId":337924,"journal":{"name":"2021 IEEE IAS Pulp and Paper Industry Conference (PPIC)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE IAS Pulp and Paper Industry Conference (PPIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPIC47846.2021.9620454","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

For the past several years, there has been confusion surrounding both factory and field testing of liquid filled distribution substation transformers installed in industry. With the advent of new ester-based fluids, new standards have been developed that impact selection, installation and maintenance of liquid-filled transformers. This article will focus on established standards for both factory and field testing and recommended tests during scheduled rotational outages. Typical ratings for distribution substation transformers applied in process industries range from 112.5 kVA through 10,000 kVA three-phase, at 50 or 60 Hertz, with primary voltage at 34,500 volts and below and secondary voltage at 4,160 volts and below. Not included in the scope of this paper are dry-type distribution transformers, pad-mounted distribution transformers or power transformers with ratings up to 100,000 kVA and 230 kVA. Field testing recommendations focus on dissolved gas analysis (DGA) testing and understanding/trending test results will be covered. A case study outlining recent testing, results and lessons learned for an integrated paper mill in the U.S. Pacific Northwest will be reviewed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
变电站变压器的选择、安装和维护建议
在过去的几年中,在工业中安装的充液变电站变压器的工厂和现场测试中一直存在混淆。随着新型酯基流体的出现,人们制定了新的标准,影响充液变压器的选择、安装和维护。本文将重点介绍工厂和现场测试的既定标准,以及在计划的轮流停机期间推荐的测试。过程工业中应用的配电变电站变压器的典型额定值范围为112.5 kVA至10,000 kVA三相,频率为50或60赫兹,一次电压为34500伏及以下,二次电压为4160伏及以下。不包括在本文范围内的干式配电变压器,垫式配电变压器或功率高达100,000 kVA和230 kVA的电力变压器。现场测试建议侧重于溶解气体分析(DGA)测试和理解/趋势测试结果。一个案例研究概述了最近的测试,结果和经验教训的综合造纸厂在美国太平洋西北地区将进行审查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Replacement of (6) 1000hp DC Drives and Motors with AC 2021 PPIC Obituary Updates of the Generator Grounding Working Group Reducing Arc Flash in Common Bus Dc Systems Recommendations for Selection, Installation and Maintenance of Substation Transformers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1