Recloser - Fuse Coordination in the Distribution System of a Non-Interconnected Zone

Luis Felipe Gaitán Cubides, Juan David Gomez Ariza, Luis Alberto Zapata Giraldo, J. Serna, Jorge Sánchez
{"title":"Recloser - Fuse Coordination in the Distribution System of a Non-Interconnected Zone","authors":"Luis Felipe Gaitán Cubides, Juan David Gomez Ariza, Luis Alberto Zapata Giraldo, J. Serna, Jorge Sánchez","doi":"10.1109/CONCAPAN48024.2022.9997734","DOIUrl":null,"url":null,"abstract":"Some towns in Colombia that are not connected to the National Interconnected System, supply their energy needs from Diesel Generation and Solar-Diesel Hybrid systems. These populations do not have uninterrupted electric energy service, reason why, in case of a transient failure in the distribution network, a great number of users may lose the electric supply, due to the performance of the protections. In this work, the implementation of reclosers in the electrical distribution system is proposed with the objective that these devices allow the disconnection of only the faulted parts of the circuit in a coordinated manner with the fuse tripping. The overcurrent functions criteria of the recloser are adjusted and a Recloser - Fuse coordination scheme with defined time characteristics in the first actuation cycle is proposed.","PeriodicalId":138415,"journal":{"name":"2022 IEEE 40th Central America and Panama Convention (CONCAPAN)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 40th Central America and Panama Convention (CONCAPAN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CONCAPAN48024.2022.9997734","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Some towns in Colombia that are not connected to the National Interconnected System, supply their energy needs from Diesel Generation and Solar-Diesel Hybrid systems. These populations do not have uninterrupted electric energy service, reason why, in case of a transient failure in the distribution network, a great number of users may lose the electric supply, due to the performance of the protections. In this work, the implementation of reclosers in the electrical distribution system is proposed with the objective that these devices allow the disconnection of only the faulted parts of the circuit in a coordinated manner with the fuse tripping. The overcurrent functions criteria of the recloser are adjusted and a Recloser - Fuse coordination scheme with defined time characteristics in the first actuation cycle is proposed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非互联区域配电系统中的重合闸-熔断器协调
哥伦比亚一些没有连接到国家互联系统的城镇,通过柴油发电和太阳能-柴油混合动力系统来满足他们的能源需求。这些人群没有不间断的电力服务,这就是为什么在配电网发生暂态故障时,由于保护的性能,大量用户可能会失去电力供应。在这项工作中,建议在配电系统中实施重合闸,目的是这些装置允许仅断开电路的故障部分,以与熔断器跳闸协调的方式。调整了重合闸的过流功能判据,提出了一种具有确定时间特性的重合闸-熔断器配合方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wireless-based pest control in tomato crops Analysis of the Crucial Factors in Biomass Electricity Generation Energy management strategies in stand alone hybrid renewable energy systems Canopy Extraction in a Banana Crop From UAV Captured Multispectral Images Multistage Decimation Filter with Decreased Complexity and Improved Aliasing Rejection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1