{"title":"A study on the new control scheme of Class-E inverter for IH-jar application with clamped voltage characteristics using pulse frequency modulation","authors":"Young-Deok Choi, Dong-Yun Lee, D. Hyun","doi":"10.1109/IAS.2002.1042732","DOIUrl":null,"url":null,"abstract":"In this paper, a new control scheme of Class-E inverter for induction heating (IH) jar applications with clamped voltage characteristics using pulse-frequency modulation (PFM) is introduced. To reduce the voltage stress of the switch, the proposed PFM control scheme doesn't need any auxiliary circuit in comparison to a family of active clamped Class E (ACCE) inverter. It can decrease voltage stress of switch through modulation of switching frequency. The Class-E inverter using the proposed control scheme has the advantages of not only the same output power when it is compared with a hybrid-active clamped Class-E (hybrid-ACCE) inverter but also zero-voltage-switching (ZVS), which are characteristics of conventional Class-E and active clamped Class-E (ACCE) inverter. The control principles of the proposed method are explained in detail and its validity is verified through experimental results.","PeriodicalId":202482,"journal":{"name":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2002.1042732","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15
Abstract
In this paper, a new control scheme of Class-E inverter for induction heating (IH) jar applications with clamped voltage characteristics using pulse-frequency modulation (PFM) is introduced. To reduce the voltage stress of the switch, the proposed PFM control scheme doesn't need any auxiliary circuit in comparison to a family of active clamped Class E (ACCE) inverter. It can decrease voltage stress of switch through modulation of switching frequency. The Class-E inverter using the proposed control scheme has the advantages of not only the same output power when it is compared with a hybrid-active clamped Class-E (hybrid-ACCE) inverter but also zero-voltage-switching (ZVS), which are characteristics of conventional Class-E and active clamped Class-E (ACCE) inverter. The control principles of the proposed method are explained in detail and its validity is verified through experimental results.